268 714

Cited 0 times in

The histometric analysis of osseointegration in hydroxyapatite surface dental implants by ion beam-assisted deposition

Authors
 Min-Kyung Kim  ;  Jung-Yoo Choi  ;  Gyung-Joon Chae  ;  Ui-Won Jung  ;  Sung-Tae Kim  ;  In-Seop Lee  ;  Kyoo-Sung Cho  ;  Chong-Kwan Kim  ;  Seong-Ho Choi 
Citation
 Journal of Korean Academy of Periodontology (대한치주과학회지), Vol.38(2 suppl) : 363-372, 2008 
Journal Title
Journal of Korean Academy of Periodontology(대한치주과학회지)
ISSN
 2093-2278 
Issue Date
2008
Keywords
Ion beam-assisted deposition method ; hydroxyapatite ; rough surface implant ; minipigs
Abstract
Purpose: This study compared the effects of coating implants with hydroxyapatite (HA) using an ion beam-assisted deposition (IBAD) method prepared with machined, anodized, sandblasted and large-grit acid etched (SLA) surfaces in minipigs, and verified the excellency of coating method with HA using IBAD. Material and Methods: 4 male Minipigs(Prestige World Genetics, Korea), 18 to 24 months old and weighing approximately 35 to 40 kg, were chosen. All premolars and first molars of the maxilla were carefully extracted on each side. The implants were placed on the right side after an 8 week healing period. The implant stability was assessed by resonance frequency analysis (RFA) at the time of placement. 40 implants were divided into 5 groups; machined, anodized, anodized plus IBAD, SLA, and SLA plus IBAD surface implants. 4 weeks after implantation on the right side, the same surface implants were placed on the left side. After 4 weeks of healing, the minipigs were sacrificed and the implants were analyzed by RFA, histology and histometric. Results: RFA showed a mean implant stability quotient (ISQ) of $75.625{\pm}5.021$, $76.125{\pm}3.739$ ISQ and $77.941{\pm}2.947$ at placement, after 4 weeks healing and after 8 weeks, respectively. Histological analysis of the implants demonstrated newly formed, compact, mature cortical bone with a nearby marrow spaces. HA coating was not separated from the HA coated implant surfaces using IBAD. In particular, the SLA implants coated with HA using IBAD showed better contact osteogenesis. Statistical and histometric analysis showed no significant differences in the bone to implant contact and bone density among 5 tested surfaces. Conclusion: We can conclude that rough surface implants coated with HA by IBAD are more biocompatible, and clinical, histological, and histometric analysis showed no differences when compared with the other established implant surfaces in normal bone
Files in This Item:
T200803337.pdf Download
DOI
10.5051/jkape.2008.38.Suppl.363
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sung Tae(김성태)
Kim, Chong Kwan(김종관)
Jung, Ui Won(정의원) ORCID logo https://orcid.org/0000-0001-6371-4172
Cho, Kyoo Sung(조규성) ORCID logo https://orcid.org/0000-0002-6777-5287
Chae, Gyung Joon(채경준)
Choi, Seong Ho(최성호) ORCID logo https://orcid.org/0000-0001-6704-6124
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/108160
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links