476 434

Cited 0 times in

두종의external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study)

Other Titles
 Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study 
Authors
 이지은  ;  허성주  ;  곽재영  ;  김성균  ;  한종현 
Citation
 Journal of Korean Academy of Prosthodontics (대한치과보철학회지), Vol.46(2) : 169-174, 2008 
Journal Title
Journal of Korean Academy of Prosthodontics(대한치과보철학회지)
ISSN
 0301-2875 
Issue Date
2008
Keywords
Marginal bone level ; Microthreads ; Rough surface
Abstract
Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with Branemark system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.
Files in This Item:
T200800666.pdf Download
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Han, Jong Hyoun(한종현)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/106914
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links