1 615

Cited 19 times in

A new automated multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) using an AP720S analyzer

Authors
 Sungsil Lee  ;  Hwan Sub Lim  ;  Jungyong Park  ;  Hyon Suk Kim 
Citation
 CLINICA CHIMICA ACTA, Vol.402(1-2) : 182-188, 2009 
Journal Title
CLINICA CHIMICA ACTA
ISSN
 0009-8981 
Issue Date
2009
MeSH
Adolescent ; Adult ; Allergens/analysis* ; Child ; Female ; Humans ; Hypersensitivity/diagnosis* ; Hypersensitivity/immunology ; Immunoglobulin E/immunology* ; Luminescent Measurements/instrumentation* ; Luminescent Measurements/methods* ; Male ; Middle Aged ; Young Adult
Keywords
Multiple allergen simultaneous test (MAST) ; Chemiluminescent assay (CLA) ; Automated analyzer AP720S ; Allergy screening ; allergen-specific IgE
Abstract
BACKGROUND: In the diagnosis of atopic diseases, allergen detection is a crucial step. Multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is a simple and noninvasive method for in vitro screening of allergen-specific IgE antibodies.

METHODS: The Korean Inhalant Panel test on 20 patients and Food Panel test on 19 patients were performed using the conventional manual MAST-CLA kit and the new automated MAST-CLA method (automated AP720S system for the Optigen Assay; Hitachi Chemical Diagnostics, Inc., USA) simultaneously. The results were evaluated for positive reactivity and concordance.

RESULTS: The results of inhalant panel gave a relatively higher class level result than the food panel. The 8 patients out of 20 (40%) of the inhalation panel, and 9 patients out of 18 (47.4%) of the food panel showed 100% concordance between the 2 systems. Eighteen patients (90%) of the Inhalation Panel and sixteen patients (84.2%) of the Food Panel showed more than 91% concordance.

CONCLUSIONS: These results suggest that the MAST-CLA assay using the new, automated AP720S analyzer performs well, showing a high concordance rate with conventional MAST-CLA. Compared to manual MAST-CLA, the automated AP720S system has a shorter assay time and uses a smaller serum volume (500 microl) along with other conveniences.
Full Text
http://www.sciencedirect.com/science/article/pii/S0009898109000254
DOI
10.1016/j.cca.2009.01.014
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Hyon Suk(김현숙) ORCID logo https://orcid.org/0000-0001-5662-7740
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/103753