1 646

Cited 20 times in

A new automated multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) using an AP720S analyzer

DC Field Value Language
dc.contributor.author김현숙-
dc.date.accessioned2015-04-24T16:33:58Z-
dc.date.available2015-04-24T16:33:58Z-
dc.date.issued2009-
dc.identifier.issn0009-8981-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/103753-
dc.description.abstractBACKGROUND: In the diagnosis of atopic diseases, allergen detection is a crucial step. Multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is a simple and noninvasive method for in vitro screening of allergen-specific IgE antibodies. METHODS: The Korean Inhalant Panel test on 20 patients and Food Panel test on 19 patients were performed using the conventional manual MAST-CLA kit and the new automated MAST-CLA method (automated AP720S system for the Optigen Assay; Hitachi Chemical Diagnostics, Inc., USA) simultaneously. The results were evaluated for positive reactivity and concordance. RESULTS: The results of inhalant panel gave a relatively higher class level result than the food panel. The 8 patients out of 20 (40%) of the inhalation panel, and 9 patients out of 18 (47.4%) of the food panel showed 100% concordance between the 2 systems. Eighteen patients (90%) of the Inhalation Panel and sixteen patients (84.2%) of the Food Panel showed more than 91% concordance. CONCLUSIONS: These results suggest that the MAST-CLA assay using the new, automated AP720S analyzer performs well, showing a high concordance rate with conventional MAST-CLA. Compared to manual MAST-CLA, the automated AP720S system has a shorter assay time and uses a smaller serum volume (500 microl) along with other conveniences.-
dc.description.statementOfResponsibilityopen-
dc.format.extent182~188-
dc.relation.isPartOfCLINICA CHIMICA ACTA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAllergens/analysis*-
dc.subject.MESHChild-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHHypersensitivity/diagnosis*-
dc.subject.MESHHypersensitivity/immunology-
dc.subject.MESHImmunoglobulin E/immunology*-
dc.subject.MESHLuminescent Measurements/instrumentation*-
dc.subject.MESHLuminescent Measurements/methods*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHYoung Adult-
dc.titleA new automated multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) using an AP720S analyzer-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorSungsil Lee-
dc.contributor.googleauthorHwan Sub Lim-
dc.contributor.googleauthorJungyong Park-
dc.contributor.googleauthorHyon Suk Kim-
dc.identifier.doi10.1016/j.cca.2009.01.014-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ00543-
dc.identifier.eissn1873-3492-
dc.identifier.pmid19263528-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0009898109000254-
dc.subject.keywordMultiple allergen simultaneous test (MAST)-
dc.subject.keywordChemiluminescent assay (CLA)-
dc.subject.keywordAutomated analyzer AP720S-
dc.subject.keywordAllergy screening-
dc.subject.keywordallergen-specific IgE-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.citation.volume402-
dc.citation.number1-2-
dc.citation.startPage182-
dc.citation.endPage188-
dc.identifier.bibliographicCitationCLINICA CHIMICA ACTA, Vol.402(1-2) : 182-188, 2009-