PURPOSE: To compare the relative values of various fast breath-hold imaging sequences for superparamagnetic iron-oxide (SPIO)-enhanced hepatic MRI for the assessment of solid focal lesions with a 3T MRI unit. MATERIALS AND METHODS: 102 consecutive patients with one or more solid malignant hepatic lesions were evaluated by spoiled gradient echo (GRE) sequences with three different echo times (2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10]) for T2*-weighted imaging in addition to T2-weighted turbo spin echo (TSE) sequence following intravenous SPIO injection. Image qualities of the hepatic contour, vascular landmarks and artifacts were rated by two independent readers using a four-point scale. For quantitative analysis, contrast-to-noise ratio (CNR) was measured in 170 solid focal lesions larger than 1 cm (107 hepatocellular carcinomas, nine cholangiocarcinomas and 54 metastases). RESULTS: GRE_5.8 showed the highest mean points for hepatic contour, vascular anatomy and imaging artifact presence among all of the subjected sequences (p<0.001) and was comparable (p=0.414) with GRE_10 with regard to lesion conspicuity. The mean CNRs were significantly higher (p<0.001) in the following order: GRE_10 (24.4+/-14.5), GRE_5.8 (14.8+/-9.4), TSE (9.7+/-6.3), and GRE_2.4 (7.9+/-6.4). The mean CNRs of CCCs and metastases were higher than those of HCCs for all imaging sequences (p<0.05). CONCLUSION: Regarding overall performances, GRE using a moderate echo time of 5.8 msec can provide the most reliable data among the various fast breath-hold SPIO-enhanced hepatic MRI sequences at 3T unit despite the lower CNR of GRE_5.8 compared to that of GRE_10
Files in This Item:
T201002932.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Ki Whang(김기황)
Kim, Joo Hee(김주희) ORCID logo https://orcid.org/0000-0001-5383-3602
Yu, Jeong Sik(유정식) ORCID logo https://orcid.org/0000-0002-8171-5838
Chung, Jae Joon(정재준) ORCID logo https://orcid.org/0000-0002-7447-1193
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/101904
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links