691 644

Cited 0 times in

Structure-function relationship and diagnostic value of macular ganglion cell complex measurement using Fourier-domain OCT in glaucoma.

Authors
 Na Rae Kim  ;  Eun Suk Lee  ;  Gong Je Seong  ;  Ji Hyun Kim  ;  Hyong Gin An  ;  Chan Yun Kim 
Citation
 INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, Vol.51(9) : 4646-4651, 2010 
Journal Title
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
ISSN
 0146-0404 
Issue Date
2010
MeSH
Adult ; Aged ; Female ; Fourier Analysis ; Glaucoma/pathology* ; Humans ; Linear Models ; Macula Lutea/pathology* ; Male ; Middle Aged ; Models, Biological ; Nerve Fibers/pathology ; Photophobia/pathology ; ROC Curve ; Retinal Ganglion Cells/pathology* ; Severity of Illness Index* ; Tomography, Optical Coherence/methods* ; Visual Fields
Abstract
PURPOSE: To assess the relationship between visual function and macular ganglion cell complex (GCC) thickness measured by Fourier-domain optical coherence tomography (OCT) and to evaluate the diagnostic value of GCC thickness for detecting early, moderate, and severe glaucoma.

METHODS: Participants underwent reliable standard automated perimetry testing and OCT imaging with optic nerve head (ONH) mode and GCC mode within a single day. The relationship between structure and function was evaluated by comparing GCC thickness with mean deviation (MD) and visual field index (VFI), by regression analysis. The results were compared with those obtained for retinal nerve fiber layer (RNFL) thickness. The area under the receiver operating characteristic curve (AUC) was used to determine the relationship between disease severity and glaucomatous changes in RNFL and GCC parameters.

RESULTS: One hundred three normal control subjects and 138 patients with glaucoma were included in the present study. Compared with linear models, second-order polynomial models better described the relationships between GCC thickness and MD (P<0.001), and between GCC thickness and VFI (P<0.001). A GCC pattern parameter, global loss volume (GLV), had the highest AUC for detecting early glaucoma. The AUC of mean GCC thickness for early glaucoma was higher than that of mean RNFL; however, the difference was not significant (P=0.330).

CONCLUSIONS: A curvilinear function best described the relationship between VF sensitivity and GCC thickness. Macular GCC thickness and RNFL thickness showed similar diagnostic performance for detecting early, moderate, and severe glaucoma.
Files in This Item:
T201002343.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Na Rae(김나래)
Kim, Ji Hyun(김지현)
Kim, Chan Yun(김찬윤) ORCID logo https://orcid.org/0000-0002-8373-9999
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
Lee, Eun Suk(이은석)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/101544
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links