Cited 18 times in
Secondary stability of microthickness hydroxyapatite-coated dental implants installed without primary stability in dogs
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김민수 | - |
dc.contributor.author | 김희진 | - |
dc.contributor.author | 이중석 | - |
dc.contributor.author | 정의원 | - |
dc.date.accessioned | 2015-01-06T17:23:37Z | - |
dc.date.available | 2015-01-06T17:23:37Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 0905-7161 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/99896 | - |
dc.description.abstract | OBJECTIVES: The objective of this study was to evaluate the secondary stability of microthickness hydroxyapatite (HA)-coated implants placed without primary stability in dogs. MATERIALS AND METHODS: A total of 48 implants were placed in six dogs. The groups were divided according to the absence or presence of primary stability and healing periods (4 and 8 weeks). Two implants for histological analysis and removal torque test in experimental group were placed without primary stability, showing rotational movement. The other two implants in control group were placed with primary stability. Mechanical test values and histometric measurements were analyzed. RESULTS: The experimental group showed significant increase in a time-dependent manner, while the mean values of the control group were constant in the mechanical tests. The HA layer remained intact, and substantial bone fragments were attached on the surface of the retrieved implant. All implants appeared to be in intimate contact with the host bone and without any inflammation after both 4 and 8 weeks of healing in histology. CONCLUSION: The HA-coated implants exhibited mechanically and histometrically comparable osseointegration after 4 weeks of healing, regardless of primary stability, and the HA-coating layer demonstrated high resistance to exfoliation. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 1169~1174 | - |
dc.relation.isPartOf | CLINICAL ORAL IMPLANTS RESEARCH | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Animals | - |
dc.subject.MESH | Coated Materials, Biocompatible | - |
dc.subject.MESH | Dental Implantation, Endosseous/methods* | - |
dc.subject.MESH | Dental Implants* | - |
dc.subject.MESH | Dental Prosthesis Design | - |
dc.subject.MESH | Dogs | - |
dc.subject.MESH | Durapatite/pharmacology* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Microscopy, Electron, Scanning | - |
dc.subject.MESH | Osseointegration | - |
dc.subject.MESH | Surface Properties | - |
dc.subject.MESH | Titanium | - |
dc.subject.MESH | Torque | - |
dc.title | Secondary stability of microthickness hydroxyapatite-coated dental implants installed without primary stability in dogs | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Periodontology (치주과학) | - |
dc.contributor.googleauthor | Ui-Won Jung | - |
dc.contributor.googleauthor | Sungtae Kim | - |
dc.contributor.googleauthor | In-Kyeong Lee | - |
dc.contributor.googleauthor | Min-Soo Kim | - |
dc.contributor.googleauthor | Jung-Seok Lee | - |
dc.contributor.googleauthor | Hee-Jin Kim | - |
dc.identifier.doi | 10.1111/clr.12226 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A01225 | - |
dc.contributor.localId | A03692 | - |
dc.contributor.localId | A00462 | - |
dc.contributor.localId | A03185 | - |
dc.relation.journalcode | J00600 | - |
dc.identifier.eissn | 1600-0501 | - |
dc.identifier.pmid | 23822196 | - |
dc.identifier.url | http://onlinelibrary.wiley.com/doi/10.1111/clr.12226/abstract | - |
dc.subject.keyword | histomorphometry | - |
dc.subject.keyword | hydroxyapatite | - |
dc.subject.keyword | implant stability | - |
dc.subject.keyword | implant surface | - |
dc.subject.keyword | titanium | - |
dc.contributor.alternativeName | Kim, Min Soo | - |
dc.contributor.alternativeName | Kim, Hee Jin | - |
dc.contributor.alternativeName | Lee, Jung Seok | - |
dc.contributor.alternativeName | Jung, Ui Won | - |
dc.contributor.affiliatedAuthor | Kim, Hee Jin | - |
dc.contributor.affiliatedAuthor | Jung, Ui Won | - |
dc.contributor.affiliatedAuthor | Kim, Min Soo | - |
dc.contributor.affiliatedAuthor | Lee, Jung Seok | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 25 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 1169 | - |
dc.citation.endPage | 1174 | - |
dc.identifier.bibliographicCitation | CLINICAL ORAL IMPLANTS RESEARCH, Vol.25(10) : 1169-1174, 2014 | - |
dc.identifier.rimsid | 53869 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.