0 575

Cited 14 times in

Three-dimensional contrast-enhanced hepatic MR imaging: comparison between a centric technique and a linear approach with partial Fourier along both slice and phase directions.

DC Field Value Language
dc.contributor.author김경아-
dc.contributor.author김명진-
dc.contributor.author정용은-
dc.date.accessioned2014-12-20T17:42:46Z-
dc.date.available2014-12-20T17:42:46Z-
dc.date.issued2011-
dc.identifier.issn1053-1807-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/95120-
dc.description.abstractPURPOSE: To compare the image quality of two variants of a three-dimensional (3D) gradient echo sequence (GRE) for hepatic MRI. MATERIALS AND METHODS: Thirty-nine patients underwent hepatic MRI on a 3.0 Tesla (T) magnet (Intera Achieva; Philips Medical Systems). The clinical protocol included two variants of a 3D GRE with fat suppression: (i) a "centric" approach, with elliptical centric k-space ordering and (ii) an "enhanced" approach using linear sampling and partial Fourier in both the slice and phase encoding direction. "Centric" and "Enhanced" 3D GRE images were obtained both precontrast (n = 32) and after gadoxetic acid injection (n = 39). Two reviewers jointly reviewed MR images for anatomic sharpness, overall contrast, homogeneity, and absence of artifacts. The liver-to-lesion signal difference ratio (SDR) was measured. Paired sample Wilcoxon test and paired t-tests were used. RESULTS: Enhanced 3D GRE images performed better than centric 3D GRE images with respect to anatomic sharpness (P = 0.0156), overall contrast (P = 0.0195), homogeneity (P < 0.0001), and absence of artifacts (P = 0.0003) on precontrast images. For postcontrast MRI, enhanced 3D GRE images showed better quality in terms of overall contrast (P = 0.0195), homogeneity (P < 0.0001), and absence of artifacts (P = 0.009). Liver-to-lesion SDR on enhanced 3D GRE images (0.48 ± 0.13) was significantly higher than that of conventional 3D GRE images (0.40 ± 0.19, P = 0.0004) on postcontrast images, but not on precontrast images. CONCLUSION: The enhanced 3D GRE sequence available on our scanner provided better hepatic image quality than the centric variant, without compromising lesion contrast.-
dc.description.statementOfResponsibilityopen-
dc.format.extent160~166-
dc.relation.isPartOfJOURNAL OF MAGNETIC RESONANCE IMAGING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAlgorithms-
dc.subject.MESHComputer Simulation-
dc.subject.MESHContrast Media-
dc.subject.MESHFemale-
dc.subject.MESHFourier Analysis-
dc.subject.MESHGadolinium DTPA*-
dc.subject.MESHHumans-
dc.subject.MESHImage Enhancement/methods*-
dc.subject.MESHImage Interpretation, Computer-Assisted/methods*-
dc.subject.MESHImaging, Three-Dimensional/methods*-
dc.subject.MESHLinear Models-
dc.subject.MESHLiver/pathology*-
dc.subject.MESHLiver Neoplasms/pathology*-
dc.subject.MESHMagnetic Resonance Imaging/methods*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHModels, Biological-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.titleThree-dimensional contrast-enhanced hepatic MR imaging: comparison between a centric technique and a linear approach with partial Fourier along both slice and phase directions.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorKyung Ah Kim-
dc.contributor.googleauthorGwenael Herigault-
dc.contributor.googleauthorMyeong-Jin Kim-
dc.contributor.googleauthorYoung Eun Chung-
dc.contributor.googleauthorHye-Suk Hong-
dc.contributor.googleauthorSun Young Choi-
dc.identifier.doi10.1002/jmri.22436-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00426-
dc.contributor.localIdA03662-
dc.contributor.localIdA00301-
dc.relation.journalcodeJ01567-
dc.identifier.eissn1522-2586-
dc.identifier.pmid21182134-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1002/jmri.22436/abstract-
dc.subject.keywordMRI-
dc.subject.keywordliver imaging-
dc.subject.keywordgadoxetic acid disodium-
dc.subject.keywordCartesian k-space ordering-
dc.subject.keywordT1-weighted gradient echo-
dc.contributor.alternativeNameKim, Kyung Ah-
dc.contributor.alternativeNameKim, Myeong Jin-
dc.contributor.alternativeNameChung, Yong Eun-
dc.contributor.affiliatedAuthorKim, Myeong Jin-
dc.contributor.affiliatedAuthorChung, Yong Eun-
dc.contributor.affiliatedAuthorKim, Kyung Ah-
dc.rights.accessRightsnot free-
dc.citation.volume33-
dc.citation.number1-
dc.citation.startPage160-
dc.citation.endPage166-
dc.identifier.bibliographicCitationJOURNAL OF MAGNETIC RESONANCE IMAGING, Vol.33(1) : 160-166, 2011-
dc.identifier.rimsid28108-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.