3D whole-heart coronary MR angiography at 1.5T in healthy volunteers: comparison between unenhanced SSFP and Gd-enhanced FLASH sequences

DC Field Value Language
dc.contributor.author권혜미-
dc.contributor.author김상진-
dc.contributor.author김태훈-
dc.contributor.author홍유진-
dc.date.accessioned2014-12-20T17:26:05Z-
dc.date.available2014-12-20T17:26:05Z-
dc.date.issued2011-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94596-
dc.description.abstractOBJECTIVE: To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). MATERIALS AND METHODS: Thirty healthy volunteers (M:F = 25:5; mean age, 35 years; range, 24-54 years) underwent a coronary MRA at 1.5T. 3D whole-heart coronary MRA with an SSFP was performed at three different times: 1) at end-systole with a narrow (120-msec) acquisition window (ESN), 2) mid-diastole with narrow acquisition (MDN); and 3) mid-diastole with wide (170-msec) acquisition (MDW). All volunteers underwent a contrast enhanced coronary MRA after undergoing an unenhanced 3D true fast imaging with steady-state precession (FISP) MRA three times. A contrast enhanced coronary MRA with FLASH was performed during MDN. Visibility of the coronary artery and image quality were evaluated for 11 segments, as suggested by the American Heart Association. Image quality was scored by a five-point scale (1 = not visible to 5 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at the proximal coronary arteries. RESULTS: The SSFP sequence rendered higher visibility coronary segments, higher image quality, as well as higher SNR and CNR than the Gd-enhanced FLASH technique at 1.5T (p < 0.05). The visibility of coronary segments, image quality, SNR and CNR in the ESN, MDN and MDW with SSFP sequence did not differ significantly. CONCLUSION: An SSFP sequence provides an excellent method for the 3D whole-heart coronary MRA at 1.5T. Contrast enhanced coronary MRA using the FLASH sequence does not help improve the visibility of coronary segments, image quality, SNR or CNR on the 3D whole-heart coronary MRA.-
dc.description.statementOfResponsibilityopen-
dc.format.extent679~685-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHContrast Media*-
dc.subject.MESHCoronary Vessels/anatomy & histology*-
dc.subject.MESHFemale-
dc.subject.MESHGadolinium-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHImaging, Three-Dimensional*-
dc.subject.MESHMagnetic Resonance Angiography/methods*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOrganometallic Compounds*-
dc.subject.MESHReference Values-
dc.subject.MESHYoung Adult-
dc.title3D whole-heart coronary MR angiography at 1.5T in healthy volunteers: comparison between unenhanced SSFP and Gd-enhanced FLASH sequences-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorHye Mi Gweon-
dc.contributor.googleauthorSang Jin Kim-
dc.contributor.googleauthorSang Min Lee-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorTae Hoon Kim-
dc.identifier.doi10.3348/kjr.2011.12.6.679-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01086-
dc.contributor.localIdA00265-
dc.contributor.localIdA00528-
dc.contributor.localIdA04422-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid22043149-
dc.subject.keyword1.5T-
dc.subject.keywordCardiac magnetic resonance-
dc.subject.keywordContrast agent-
dc.subject.keywordCoronary artery imaging-
dc.subject.keywordFast low-angle shot-
dc.subject.keywordSteady-state free precession-
dc.contributor.alternativeNameGweon, Hye Mi-
dc.contributor.alternativeNameKim, Sang Jin-
dc.contributor.alternativeNameKim, Tae Hoon-
dc.contributor.alternativeNameHong, Yoo Jin-
dc.contributor.affiliatedAuthorKim, Tae Hoon-
dc.contributor.affiliatedAuthorGweon, Hye Mi-
dc.contributor.affiliatedAuthorKim, Sang Jin-
dc.contributor.affiliatedAuthorHong, Yoo Jin-
dc.rights.accessRightsfree-
dc.citation.volume12-
dc.citation.number6-
dc.citation.startPage679-
dc.citation.endPage685-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.12(6) : 679-685, 2011-
dc.identifier.rimsid27439-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.