Cited 34 times in
Clinical experiences of digital model surgery and the rapid-prototyped wafer for maxillary orthognathic surgery
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이상휘 | - |
dc.contributor.author | 이채은 | - |
dc.contributor.author | 이충국 | - |
dc.contributor.author | 박원서 | - |
dc.contributor.author | 유형석 | - |
dc.date.accessioned | 2014-12-20T16:35:08Z | - |
dc.date.available | 2014-12-20T16:35:08Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 1079-2104 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/92994 | - |
dc.description.abstract | OBJECTIVE: The aim of this study was to present our clinical experience regarding the production and accuracy of digitally printed wafers for maxillary movement during the bimaxillary orthognathic surgery. STUDY DESIGN: Fifty-five consecutive patients requiring maxillary orthognathic surgery were included in this study. The plan for digital model surgery (DMS) was dictated by the surgical plans for each clinical case. We carried out digital model mounting, DMS, wafer printing, and confirmation of the accuracy of the procedure. RESULTS: Moving the reference points to the target position in DMS involved a mean error of 0.00-0.09 mm. The mean errors confirmed by the model remounting procedure with the printed wafer by DMS were 0.18-0.40 mm (for successful cases; n = 42) and 0.03-1.04 mm (for poor cases; n = 3). CONCLUSION: The accuracies of the wafers by DMS were similar to those for wafers produced by manual model surgery, although they were less accurate than those produced by DMS alone. The rapid-prototyped interocclusal wafer produced with the aid of DMS can be an alternative procedure for maxillary orthognathic surgery. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Elsevier | - |
dc.relation.isPartOf | ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Cephalometry/methods | - |
dc.subject.MESH | Computer-Aided Design* | - |
dc.subject.MESH | Craniofacial Abnormalities/surgery | - |
dc.subject.MESH | Dental Articulators | - |
dc.subject.MESH | Dental Models | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Imaging, Three-Dimensional/methods | - |
dc.subject.MESH | Jaw Relation Record/instrumentation* | - |
dc.subject.MESH | Malocclusion/surgery | - |
dc.subject.MESH | Maxilla/abnormalities | - |
dc.subject.MESH | Maxilla/surgery* | - |
dc.subject.MESH | Models, Anatomic* | - |
dc.subject.MESH | Orthognathic Surgical Procedures/instrumentation | - |
dc.subject.MESH | Orthognathic Surgical Procedures/methods* | - |
dc.subject.MESH | Patient Care Planning* | - |
dc.subject.MESH | Tomography, X-Ray Computed/methods | - |
dc.subject.MESH | User-Computer Interface | - |
dc.title | Clinical experiences of digital model surgery and the rapid-prototyped wafer for maxillary orthognathic surgery | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Oral and Maxillofacial Surgery (구강악안면외과학) | - |
dc.contributor.googleauthor | Bong Chul Kim | - |
dc.contributor.googleauthor | Chae Eun Lee | - |
dc.contributor.googleauthor | Wonse Park | - |
dc.contributor.googleauthor | Moon-Key Kim | - |
dc.contributor.googleauthor | Piao Zhengguo | - |
dc.contributor.googleauthor | Hyung-Seog Yu | - |
dc.contributor.googleauthor | Choong Kook Yi | - |
dc.contributor.googleauthor | Sang-Hwy Lee | - |
dc.identifier.doi | 10.1016/j.tripleo.2010.04.038 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A02839 | - |
dc.contributor.localId | A03251 | - |
dc.contributor.localId | A03258 | - |
dc.contributor.localId | A01589 | - |
dc.contributor.localId | A02532 | - |
dc.relation.journalcode | J02443 | - |
dc.identifier.eissn | 1528-395X | - |
dc.identifier.pmid | 20692187 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S107921041000291X | - |
dc.contributor.alternativeName | Lee, Sang Hwy | - |
dc.contributor.alternativeName | Lee, Chae Eun | - |
dc.contributor.alternativeName | Yi, Choong Kook | - |
dc.contributor.alternativeName | Park, Wonse | - |
dc.contributor.alternativeName | Yu, Hyung Seog | - |
dc.contributor.affiliatedAuthor | Lee, Sang Hwy | - |
dc.contributor.affiliatedAuthor | Lee, Chae Eun | - |
dc.contributor.affiliatedAuthor | Yi, Choong Kook | - |
dc.contributor.affiliatedAuthor | Park, Wonse | - |
dc.contributor.affiliatedAuthor | Yu, Hyung Seog | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 111 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 278 | - |
dc.citation.endPage | 285.e1 | - |
dc.identifier.bibliographicCitation | ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, Vol.111(3) : 278-285.e1, 2011 | - |
dc.identifier.rimsid | 27958 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.