437 646

Cited 114 times in

Cardioembolic stroke: dual-energy cardiac CT for differentiation of left atrial appendage thrombus and circulatory stasis

DC Field Value Language
dc.contributor.author허진-
dc.contributor.author홍유진-
dc.contributor.author김영진-
dc.contributor.author김희영-
dc.contributor.author남지은-
dc.contributor.author이지원-
dc.contributor.author이혜정-
dc.contributor.author최병욱-
dc.date.accessioned2014-12-19T17:38:12Z-
dc.date.available2014-12-19T17:38:12Z-
dc.date.issued2012-
dc.identifier.issn0033-8419-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/91783-
dc.description.abstractPURPOSE: To assess the diagnostic performance of dual-energy cardiac computed tomography (CT) in the detection of left atrial appendage (LAA) thrombi and differentiation between thrombus and circulatory stasis in patients with stroke, by using transesophageal echocardiography (TEE) as the reference standard. MATERIALS AND METHODS: The institutional review board approved this study, and patients provided informed consent. Thirty-two patients with stroke who had atrial fibrillation (AF) and either thrombus or the spontaneous echo contrast (SEC) echo pattern at TEE were prospectively enrolled. For the control group, 31 patients who were planning to undergo AF ablation and who had no abnormalities at TEE were enrolled. All patients underwent dual-energy cardiac CT that was not electrocardiographically gated. For quantitative analysis, iodine concentration was measured on CT images. The statistical significance of differences in mean iodine concentration between thrombus and SEC as measured at CT was assessed by using the Student t test. RESULTS: Among the 63 patients, a total of 13 thrombi and 19 instances of SEC were detected at TEE. Using TEE as the reference standard, the overall sensitivity, specificity, positive predictive value, and negative predictive value of dual-energy cardiac CT in the detection of thrombi and SEC in the LAA were 97% (95% confidence interval [CI]: 82%, 100%), 100% (95% CI: 86%, 100%), 100%, and 97%, respectively. At CT, the mean iodine concentration was 1.23 mg/mL ± 0.34 (standard deviation) for thrombus and 3.61 mg/mL ± 1.01 for SEC (P = .001). CONCLUSION: Dual-energy cardiac CT is a highly sensitive modality for detecting LAA thrombus and for differentiating thrombus from SEC in patients with stroke.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfRADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHAtrial Appendage/diagnostic imaging*-
dc.subject.MESHCase-Control Studies-
dc.subject.MESHChi-Square Distribution-
dc.subject.MESHContrast Media-
dc.subject.MESHCoronary Circulation-
dc.subject.MESHCoronary Thrombosis/complications*-
dc.subject.MESHCoronary Thrombosis/diagnostic imaging*-
dc.subject.MESHDiagnosis, Differential-
dc.subject.MESHEchocardiography, Transesophageal-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPredictive Value of Tests-
dc.subject.MESHProspective Studies-
dc.subject.MESHROC Curve-
dc.subject.MESHRadiographic Image Interpretation, Computer-Assisted-
dc.subject.MESHRisk Factors-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHStroke/etiology*-
dc.subject.MESHTomography, X-Ray Computed/methods*-
dc.subject.MESHTriiodobenzoic Acids-
dc.titleCardioembolic stroke: dual-energy cardiac CT for differentiation of left atrial appendage thrombus and circulatory stasis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorJin Hur-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorHye-Jeong Lee-
dc.contributor.googleauthorJi Eun Nam-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorHee Yeong Kim-
dc.contributor.googleauthorJi Won Lee-
dc.contributor.googleauthorByoung Wook Choi-
dc.identifier.doi10.1148/radiol.12111691-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00727-
dc.contributor.localIdA03204-
dc.contributor.localIdA03320-
dc.contributor.localIdA04370-
dc.contributor.localIdA04422-
dc.contributor.localIdA01213-
dc.contributor.localIdA01269-
dc.contributor.localIdA04059-
dc.relation.journalcodeJ02596-
dc.identifier.eissn1527-1315-
dc.identifier.pmid22495682-
dc.contributor.alternativeNameHur, Jin-
dc.contributor.alternativeNameHong, Yoo Jin-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.alternativeNameKim, Hee Yeong-
dc.contributor.alternativeNameNam, Ji Eun-
dc.contributor.alternativeNameLee, Ji Won-
dc.contributor.alternativeNameLee, Hye Jeong-
dc.contributor.alternativeNameChoi, Byoung Wook-
dc.contributor.affiliatedAuthorKim, Young Jin-
dc.contributor.affiliatedAuthorLee, Ji Won-
dc.contributor.affiliatedAuthorLee, Hye Jeong-
dc.contributor.affiliatedAuthorHur, Jin-
dc.contributor.affiliatedAuthorHong, Yoo Jin-
dc.contributor.affiliatedAuthorKim, Hee Yeong-
dc.contributor.affiliatedAuthorNam, Ji Eun-
dc.contributor.affiliatedAuthorChoi, Byoung Wook-
dc.citation.volume263-
dc.citation.number3-
dc.citation.startPage688-
dc.citation.endPage695-
dc.identifier.bibliographicCitationRADIOLOGY, Vol.263(3) : 688-695, 2012-
dc.identifier.rimsid31189-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.