Cited 0 times in
The diagnostic values of ultrasound and ultrasound-guided fine needle aspiration in subcentimeter-sized thyroid nodules
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 곽진영 | - |
dc.contributor.author | 김은경 | - |
dc.contributor.author | 문희정 | - |
dc.contributor.author | 손은주 | - |
dc.date.accessioned | 2014-12-19T16:26:38Z | - |
dc.date.available | 2014-12-19T16:26:38Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 1068-9265 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/89537 | - |
dc.description.abstract | BACKGROUND: The diagnostic performances of ultrasound (US) examination and US-guided fine needle aspiration (US-FNA) were investigated in thyroid nodules ≤10 mm in size. METHODS: From April 2006 to December 2006, 1440 nodules ≤10 mm in size in 1403 patients (mean age, 49.3 years; range, 10-84 years) underwent US and US-FNA. The association between nodule size and inadequate specimen was investigated using the Cochran-Armitage trend test and multivariate logistic regression analysis. To evaluate the diagnostic performances of US and US-FNA, we selected 852 nodules that had undergone surgery, follow-up US-FNA, or follow-up US. A receiver operating characteristic (ROC) curve analysis was used to determine the accuracies of US and US-FNA. RESULTS: Of 1440 nodules, 256 (17.8%) yielded inadequate specimens. As the nodule size increased, the rate of inadequate specimens decreased (P < 0.001). A size of 6 mm demonstrated statistical significance between inadequate and adequate specimens (P < 0.001). The diagnostic accuracy of US was slightly improved as nodule size increased. The false positive rate of US examination was higher in nodules ≤6 mm compared with that of nodules >6 mm in size (P = 0.049). However, US-FNA demonstrated high diagnostic performance in all nodules with adequate specimen. CONCLUSIONS: The inadequate specimens of US-FNA and false positives for US examinations increased as nodule size decreased. However, US-FNA demonstrated good diagnostic accuracy, assuming the specimen was adequate. | - |
dc.description.statementOfResponsibility | open | - |
dc.relation.isPartOf | ANNALS OF SURGICAL ONCOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adolescent | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Biopsy, Fine-Needle | - |
dc.subject.MESH | Carcinoma, Papillary/diagnosis* | - |
dc.subject.MESH | Carcinoma, Papillary/surgery | - |
dc.subject.MESH | Child | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Follow-Up Studies | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Prognosis | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Thyroid Neoplasms/diagnosis* | - |
dc.subject.MESH | Thyroid Neoplasms/surgery | - |
dc.subject.MESH | Thyroid Nodule/diagnosis* | - |
dc.subject.MESH | Thyroid Nodule/surgery | - |
dc.subject.MESH | Thyroidectomy | - |
dc.subject.MESH | Ultrasonics* | - |
dc.subject.MESH | Young Adult | - |
dc.title | The diagnostic values of ultrasound and ultrasound-guided fine needle aspiration in subcentimeter-sized thyroid nodules | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Hee Jung Moon | - |
dc.contributor.googleauthor | Eunju Son | - |
dc.contributor.googleauthor | Eun-Kyung Kim | - |
dc.contributor.googleauthor | Jung Hyun Yoon | - |
dc.contributor.googleauthor | Jin Young Kwak | - |
dc.identifier.doi | 21638096 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00182 | - |
dc.contributor.localId | A00801 | - |
dc.contributor.localId | A01397 | - |
dc.contributor.localId | A01988 | - |
dc.relation.journalcode | J00179 | - |
dc.identifier.eissn | 1534-4681 | - |
dc.identifier.pmid | 21638096 | - |
dc.identifier.url | http://link.springer.com/article/10.1245%2Fs10434-011-1813-1 | - |
dc.subject.keyword | Nodule | - |
dc.subject.keyword | Papillary Thyroid Carcinoma | - |
dc.subject.keyword | Fine Needle Aspiration | - |
dc.subject.keyword | Diagnostic Performance | - |
dc.subject.keyword | Thyroid Nodule | - |
dc.contributor.alternativeName | Kwak, Jin Young | - |
dc.contributor.alternativeName | Kim, Eun Kyung | - |
dc.contributor.alternativeName | Moon, Heui Jeong | - |
dc.contributor.alternativeName | Son, Eun Ju | - |
dc.contributor.affiliatedAuthor | Kwak, Jin Young | - |
dc.contributor.affiliatedAuthor | Kim, Eun-Kyung | - |
dc.contributor.affiliatedAuthor | Moon, Heui Jeong | - |
dc.contributor.affiliatedAuthor | Son, Eun Ju | - |
dc.citation.volume | 19 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 52 | - |
dc.citation.endPage | 59 | - |
dc.identifier.bibliographicCitation | ANNALS OF SURGICAL ONCOLOGY, Vol.19(1) : 52-59, 2012 | - |
dc.identifier.rimsid | 31479 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.