234 504

Cited 7 times in

Clinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard

DC Field Value Language
dc.contributor.author곽진영-
dc.contributor.author손은주-
dc.date.accessioned2014-12-18T09:14:32Z-
dc.date.available2014-12-18T09:14:32Z-
dc.date.issued2013-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/87800-
dc.description.abstractOBJECTIVE: The goal of this study is to compare the overall quality of film mammograms taken according to the Korean standards with the American College of Radiology (ACR) standard for clinical image evaluation and to identify means of improving mammography quality in Korea. MATERIALS AND METHODS: Four hundred and sixty eight sets of film mammograms were evaluated with respect to the Korean and ACR standards for clinical image evaluation. The pass and failure rates of mammograms were compared by medical facility types. Average scores in each category of the two standards were evaluated. Receiver operating characteristic curve analysis was used to identify an optimal Korean standard pass mark by taking the ACR standard as the reference standard. RESULTS: 93.6% (438/468) of mammograms passed the Korean standard, whereas only 80.1% (375/468) passed the ACR standard (p < 0.001). Non-radiologic private clinics had the lowest pass rate (88.1%: Korean standard, 71.8%: ACR standard) and the lowest total score (76.0) by the Korean standard. Average scores of positioning were lowest (19.3/29 by the Korean standard and 3.7/5 by the ACR standard). A cutoff score of 77.0 for the Korean standard was found to correspond to a pass level when the ACR standard was applied. CONCLUSION: We suggest that tighter regulations, such as, raising the Korean pass mark, subtracting more for severe deficiencies, or considering a very low scores in even a single category as failure, are needed to improve the quality of mammography in Korea.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAccreditation/standards*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMammography/standards*-
dc.subject.MESHQuality Improvement*-
dc.subject.MESHROC Curve-
dc.subject.MESHRepublic of Korea-
dc.subject.MESHRetrospective Studies-
dc.titleClinical Image Evaluation of Film Mammograms in Korea: Comparison with the ACR Standard-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorYeon Joo Gwak-
dc.contributor.googleauthorHye Jung Kim-
dc.contributor.googleauthorJin Young Kwak-
dc.contributor.googleauthorEun Ju Son-
dc.contributor.googleauthorKyung Hee Ko-
dc.contributor.googleauthorJin Hwa Lee-
dc.contributor.googleauthorHyo Soon Lim-
dc.contributor.googleauthorYou Jin Lee-
dc.contributor.googleauthorJi Won Park-
dc.contributor.googleauthorKyung Min Shin-
dc.contributor.googleauthorYun-Jin Jang-
dc.identifier.doi10.3348/kjr.2013.14.5.701-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00182-
dc.contributor.localIdA01988-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid24043961-
dc.subject.keywordAccreditation-
dc.subject.keywordBreast-
dc.subject.keywordMammography-
dc.subject.keywordQuality assurance-
dc.contributor.alternativeNameKwak, Jin Young-
dc.contributor.alternativeNameSon, Eun Ju-
dc.contributor.affiliatedAuthorKwak, Jin Young-
dc.contributor.affiliatedAuthorSon, Eun Ju-
dc.rights.accessRightsfree-
dc.citation.volume14-
dc.citation.number5-
dc.citation.startPage701-
dc.citation.endPage710-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.14(5) : 701-710, 2013-
dc.identifier.rimsid32277-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.