1 550

Cited 32 times in

Performance of the Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories

Authors
 Hee-Won Moon  ;  Sun Hwa Lee  ;  Hae-Sun Chung  ;  Miae Lee  ;  Kyungwon Lee 
Citation
 JOURNAL OF MEDICAL MICROBIOLOGY, Vol.62(9) : 1301-1306, 2013 
Journal Title
JOURNAL OF MEDICAL MICROBIOLOGY
ISSN
 0022-2615 
Issue Date
2013
MeSH
Bacteriological Techniques/methods ; Enterococcus faecalis/genetics ; Enterococcus faecalis/isolation & purification* ; Humans ; Laboratories/standards ; RNA, Bacterial/genetics ; RNA, Ribosomal, 16S/genetics ; Reproducibility of Results ; Sensitivity and Specificity ; Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods* ; Staphylococcus aureus/genetics ; Staphylococcus aureus/isolation & purification* ; Streptococcus agalactiae/genetics ; Streptococcus agalactiae/isolation & purification*
Keywords
Bacteriological Techniques/methods ; Enterococcus faecalis/genetics ; Enterococcus faecalis/isolation & purification* ; Humans ; Laboratories/standards ; RNA, Bacterial/genetics ; RNA, Ribosomal, 16S/genetics ; Reproducibility of Results ; Sensitivity and Specificity ; Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods* ; Staphylococcus aureus/genetics ; Staphylococcus aureus/isolation & purification* ; Streptococcus agalactiae/genetics ; Streptococcus agalactiae/isolation & purification*
Abstract
We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS correctly identified the species of 97.2 % of the staphylococci (95.9 % of coagulase-negative staphylococci), 97.8 % of the streptococci, and 100 % of the enterococci. For the identification of Gram-positive cocci isolates, the overall concordance rate between conventional identification and the Vitek MS was 94.5 %. The Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) system can be a reliable and rapid method for the identification of most relevant Gram-positive cocci. In addition, expanding the database of the Vitek MS, especially for coagulase-negative staphylococci, is needed to enhance the performance of the Vitek MS.
Full Text
http://jmm.sgmjournals.org/content/62/Pt_9/1301.long
DOI
10.1099/jmm.0.062950-0
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Lee, Kyungwon(이경원) ORCID logo https://orcid.org/0000-0003-3788-2134
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/87583
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links