936 886

Cited 0 times in

치경부 마모에 따른 상아질 지각과민증 감소를 위한 Er:Cr:YSGG 레이저 조사에 대한 임상 평가

Other Titles
 Clinical assessment on application of Er:Cr:YSGG laser in dentinal hypersensitivity reduction 
Authors
 김진유  ;  임채선  ;  경규영  ;  김기덕  ;  정복영 
Citation
 Journal of Korean Academy of Oral Health (대한구강보건학회지), Vol.37(1) : 3-8, 2013 
Journal Title
Journal of Korean Academy of Oral Health(대한구강보건학회지)
ISSN
 1225-388X 
Issue Date
2013
Keywords
Dentinal hypersensitivity ; Dentinal tubule occlusion ; Er:Cr:YSGG laser
Abstract
Objectives
We aimed to evaluate the effectiveness of Er:Cr:YSGG laser therapy on the reduction of dentinal hypersensitivity while taking into account the length and depth of the cervical abrasion.

Methods
We included adults (age, 20-60 years) with at least 2 hypersensitive teeth. The hypersensitive teeth were stimulated with a pressure-indicating probe and an air syringe. The response of the subjects to this stimulation was quantified using a visual analog scale (VAS) and Schiff air sensitivity score. The patients were treated at baseline, immediately after laser treatment, and at 1, 2, and 4 weeks after the Er:Cr:YSGG laser therapy. The results were analyzed by repeated measure analysis of variance (ANOVA) and Bonferroni's post hoc test.

Results
The values of tactile test and air blast test showed statistically significant differences between the following time points: baseline and immediately after laser treatment, baseline and first week after treatment, and immediately after laser treatment and first week after treatment (P<0.05). No statistically significant differences were observed in the VAS values of the tactile test and Schiff air sensitivity score of the air blast test between the first and second, first and fourth, and second and fourth weeks after treatment (P>0.05). The depth and width of the cervical abrasion was not statistically significant in dentinal hypersensitivity reduction (P>0.05).

Conclusions
The use of Er:Cr:YSGG laser therapy reduced dentinal hypersensitivity, especially immediately after laser treatment. The depth and width of the cervical abrasion is not statistically significant in dentinal hypersensitivity reduction.
Files in This Item:
T201302664.pdf Download
DOI
10.11149/jkaoh.2013.37.1.3
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Advanced General Dentistry (통합치의학과) > 1. Journal Papers
Yonsei Authors
Kim, Kee Deog(김기덕) ORCID logo https://orcid.org/0000-0003-3055-5130
Jung, Bok Yeong(정복영) ORCID logo https://orcid.org/0000-0002-8186-2109
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/87530
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links