389 731

Cited 12 times in

Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment

DC Field Value Language
dc.contributor.author김승호-
dc.contributor.author박인철-
dc.contributor.author유제성-
dc.contributor.author이한식-
dc.contributor.author이혜선-
dc.contributor.author장철호-
dc.contributor.author정성필-
dc.date.accessioned2014-12-18T09:03:23Z-
dc.date.available2014-12-18T09:03:23Z-
dc.date.issued2013-
dc.identifier.issn1472-0205-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/87449-
dc.description.abstractBACKGROUND: In real cardiopulmonary resuscitation (CPR), noise can arise from instructional voices and environmental sounds in places such as a battlefield and industrial and high-traffic areas. A feedback device using a flashing light was designed to overcome noise-induced stimulus saturation during CPR. This study was conducted to determine whether 'flashlight' guidance influences CPR performance in a simulated noisy setting. MATERIALS AND METHODS: We recruited 30 senior medical students with no previous experience of using flashlight-guided CPR to participate in this prospective, simulation-based, crossover study. The experiment was conducted in a simulated noisy situation using a cardiac arrest model without ventilation. Noise such as patrol car and fire engine sirens was artificially generated. The flashlight guidance device emitted light pulses at the rate of 100 flashes/min. Participants also received instructions to achieve the desired rate of 100 compressions/min. CPR performances were recorded with a Resusci Anne mannequin with a computer skill-reporting system. RESULTS: There were significant differences between the control and flashlight groups in mean compression rate (MCR), MCR/min and visual analogue scale. However, there were no significant differences in correct compression depth, mean compression depth, correct hand position, and correctly released compression. The flashlight group constantly maintained the pace at the desired 100 compressions/min. Furthermore, the flashlight group had a tendency to keep the MCR constant, whereas the control group had a tendency to decrease it after 60 s. CONCLUSION: Flashlight-guided CPR is particularly advantageous for maintaining a desired MCR during hands-only CPR in noisy environments, where metronome pacing might not be clearly heard.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfEMERGENCY MEDICINE JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHCardiopulmonary Resuscitation/methods*-
dc.subject.MESHCardiopulmonary Resuscitation/standards-
dc.subject.MESHConsumer Behavior-
dc.subject.MESHFemale-
dc.subject.MESHHeart Arrest/therapy*-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHNoise*-
dc.subject.MESHPhotic Stimulation*/methods-
dc.titleEffects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology (마취통증의학)-
dc.contributor.googleauthorJe Sung You-
dc.contributor.googleauthorSung Phil Chung-
dc.contributor.googleauthorChul Ho Chang-
dc.contributor.googleauthorIncheol Park-
dc.contributor.googleauthorHye Sun Lee3-
dc.contributor.googleauthorSeungHo Kim-
dc.contributor.googleauthorHahn Shick Lee-
dc.identifier.doi10.1136/emermed-2012-201605-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01628-
dc.contributor.localIdA02507-
dc.contributor.localIdA03278-
dc.contributor.localIdA03485-
dc.contributor.localIdA03625-
dc.contributor.localIdA00667-
dc.contributor.localIdA03312-
dc.relation.journalcodeJ00766-
dc.identifier.eissn1472-0213-
dc.identifier.pmid22927635-
dc.subject.keywordCT/MRI-
dc.subject.keywordCardiopulmonary resuscitation-
dc.subject.keywordacute coronary syndrome-
dc.subject.keywordairway-
dc.subject.keywordanaesthesia—general-
dc.subject.keywordchest compression-
dc.subject.keywordemergency care systems-
dc.subject.keywordflashlight-
dc.subject.keywordimaging-
dc.subject.keywordnoise-
dc.subject.keywordstroke-
dc.subject.keywordtrauma-
dc.subject.keywordultrasound-
dc.contributor.alternativeNameKim, Seung Ho-
dc.contributor.alternativeNamePark, In Cheol-
dc.contributor.alternativeNameYou, Je Sung-
dc.contributor.alternativeNameLee, Hahn Shick-
dc.contributor.alternativeNameLee, Hye Sun-
dc.contributor.alternativeNameChang, Chul Ho-
dc.contributor.alternativeNameChung, Sung Pil-
dc.contributor.affiliatedAuthorPark, In Cheol-
dc.contributor.affiliatedAuthorYou, Je Sung-
dc.contributor.affiliatedAuthorLee, Hahn Shick-
dc.contributor.affiliatedAuthorChang, Chul Ho-
dc.contributor.affiliatedAuthorChung, Sung Pil-
dc.contributor.affiliatedAuthorKim, Seung Ho-
dc.contributor.affiliatedAuthorLee, Hye Sun-
dc.rights.accessRightsfree-
dc.citation.volume30-
dc.citation.number8-
dc.citation.startPage628-
dc.citation.endPage632-
dc.identifier.bibliographicCitationEMERGENCY MEDICINE JOURNAL, Vol.30(8) : 628-632, 2013-
dc.identifier.rimsid34235-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Emergency Medicine (응급의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.