307 668

Cited 32 times in

Four-Dimensional Real-Time Cine Images of Wrist Joint Kinematics Using Dual Source CT with Minimal Time Increment Scanning

DC Field Value Language
dc.contributor.author김성준-
dc.contributor.author서진석-
dc.contributor.author송호택-
dc.contributor.author이영한-
dc.contributor.author조희우-
dc.contributor.author최윤성-
dc.date.accessioned2014-12-18T08:57:21Z-
dc.date.available2014-12-18T08:57:21Z-
dc.date.issued2013-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/87263-
dc.description.abstractPURPOSE: To validate the feasibility of real time kinematography with four-dimensional (4D) dynamic functional wrist joint imaging using dual source CT. MATERIALS AND METHODS: Two healthy volunteers performed radioulnar deviation and pronation- supination wrist motions for 10 s and 4 s per cycle in a dual source CT scanner. Scan and reconstruction protocols were set to optimize temporal resolution. Cine images of the reconstructed carpal bone of the moving wrist were recorded. The quality of the images and radiation dosage were evaluated. RESULTS: The 4D cine images obtained during 4 s and 10 s of radioulnar motion showed a smooth stream of movement with good quality and little noise or artifact. Images from the pronation-supination motion showed noise with a masked surface contour. The temporal resolution was optimized at 0.28 s. CONCLUSION: Using dual source CT, 4D cine images of in vivo kinematics of wrist joint movement were obtained and found to have a shorter scan time, improved temporal resolution and lower radiation dosages compared with those previously reported.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHArtifacts-
dc.subject.MESHBiomechanical Phenomena-
dc.subject.MESHCarpal Bones/diagnostic imaging-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHNontherapeutic Human Experimentation-
dc.subject.MESHRadiation Dosage-
dc.subject.MESHRadiographic Image Interpretation, Computer-Assisted/methods-
dc.subject.MESHTomography, X-Ray Computed/methods*-
dc.subject.MESHWrist Joint/diagnostic imaging*-
dc.subject.MESHWrist Joint/physiology*-
dc.titleFour-Dimensional Real-Time Cine Images of Wrist Joint Kinematics Using Dual Source CT with Minimal Time Increment Scanning-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorYoon Seong Choi-
dc.contributor.googleauthorYoung Han Lee-
dc.contributor.googleauthorSungjun Kim-
dc.contributor.googleauthorHee Woo Cho-
dc.contributor.googleauthorHo-Taek Song-
dc.contributor.googleauthorJin-Suck Suh-
dc.identifier.doi10.3349/ymj.2013.54.4.1026-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00585-
dc.contributor.localIdA01916-
dc.contributor.localIdA02080-
dc.contributor.localIdA02967-
dc.contributor.localIdA03945-
dc.contributor.localIdA04137-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid23709441-
dc.subject.keywordDual source-
dc.subject.keywordcarpal kinematics-
dc.subject.keywordcomputed tomography-
dc.subject.keyworddynamic imaging-
dc.subject.keywordfour dimensional-
dc.contributor.alternativeNameKim, Sung Jun-
dc.contributor.alternativeNameSuh, Jin Suck-
dc.contributor.alternativeNameSong, Ho Taek-
dc.contributor.alternativeNameLee, Young Han-
dc.contributor.alternativeNameCho, Hee Woo-
dc.contributor.alternativeNameChoi, Yoon Seong-
dc.contributor.affiliatedAuthorKim, Sung Jun-
dc.contributor.affiliatedAuthorSuh, Jin Suck-
dc.contributor.affiliatedAuthorSong, Ho Taek-
dc.contributor.affiliatedAuthorLee, Young Han-
dc.contributor.affiliatedAuthorCho, Hee Woo-
dc.contributor.affiliatedAuthorChoi, Yoon Seong-
dc.rights.accessRightsfree-
dc.citation.volume54-
dc.citation.number4-
dc.citation.startPage1026-
dc.citation.endPage1032-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.54(4) : 1026-1032, 2013-
dc.identifier.rimsid32934-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.