Cited 5 times in
Effect of Belly Board with Bladder Compression Device on Small Bowel Displacement from the Radiotherapy Field for Rectal Cancer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 금기창 | - |
dc.contributor.author | 금웅섭 | - |
dc.contributor.author | 남기창 | - |
dc.contributor.author | 윤홍인 | - |
dc.contributor.author | 정윤선 | - |
dc.contributor.author | 최원훈 | - |
dc.date.accessioned | 2014-12-18T08:46:09Z | - |
dc.date.available | 2014-12-18T08:46:09Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 0378-584X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/86917 | - |
dc.description.abstract | BACKGROUND: The aim of this study was to investigate the effect of a belly board (BB) with the addition of a bladder compression device (BCD) for small bowel (SB) displacement from the radiotherapy field for rectal cancer. PATIENTS AND METHODS: Computed tomography (CT) scans of 38 rectal cancer patients positioned on a BB were analyzed and compared with CT scans from the same patients after the addition of a BCD. The BCD moves the inferior border of the BB from the pubic symphysis to the lumbosacral junction. The treated and irradiated volumes of the SB and bladder were compared. The irradiated volume ratio of SB to abdominopelvic cavity (APC) and that of bladder to APC were analyzed. RESULTS: With the BCD, the treated and irradiated volumes of SB decreased significantly (49.1 ± 48.0 vs. 60.9 ± 50.9 cc, p = 0.006 and 207.5 ± 140.8 vs. 482.8 ± 214.2 cc, p < 0.001, respectively). The irradiated volume ratio of bladder to APC with the BCD increased considerably compared to that without the BCD (25.2 ± 11.5 vs. 18.7 ± 10.5%, p < 0.001), and the ratio of irradiated volume of SB to APC decreased significantly with the BCD (18.8 ± 12.4 vs. 31.8 ± 12.1%, p < 0.001). CONCLUSION: This study showed that the addition of a BCD to the BB could effectively provide further displacement of SB from the rectal cancer radiotherapy field. | - |
dc.description.statementOfResponsibility | open | - |
dc.relation.isPartOf | ONKOLOGIE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Equipment Design | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Immobilization/instrumentation* | - |
dc.subject.MESH | Immobilization/methods | - |
dc.subject.MESH | Intestine, Small/radiation effects | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Organs at Risk | - |
dc.subject.MESH | Patient Positioning/instrumentation* | - |
dc.subject.MESH | Patient Positioning/methods | - |
dc.subject.MESH | Radiation Injuries/etiology | - |
dc.subject.MESH | Radiation Injuries/prevention & control* | - |
dc.subject.MESH | Radiotherapy Setup Errors/prevention & control* | - |
dc.subject.MESH | Radiotherapy, Conformal/adverse effects* | - |
dc.subject.MESH | Radiotherapy, Conformal/instrumentation | - |
dc.subject.MESH | Rectal Neoplasms/complications | - |
dc.subject.MESH | Rectal Neoplasms/radiotherapy* | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Treatment Outcome | - |
dc.subject.MESH | Urinary Bladder* | - |
dc.title | Effect of Belly Board with Bladder Compression Device on Small Bowel Displacement from the Radiotherapy Field for Rectal Cancer | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiation Oncology (방사선종양학) | - |
dc.contributor.googleauthor | Yoonsun Chung | - |
dc.contributor.googleauthor | Hong I. Yoon | - |
dc.contributor.googleauthor | Ki C. Keum | - |
dc.contributor.googleauthor | Joo H. Kim | - |
dc.contributor.googleauthor | Won H. Choi | - |
dc.contributor.googleauthor | Ki C. Nam | - |
dc.contributor.googleauthor | Woong S. Koom | - |
dc.identifier.doi | 10.1159/000350299 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00272 | - |
dc.contributor.localId | A00273 | - |
dc.contributor.localId | A01242 | - |
dc.contributor.localId | A03678 | - |
dc.contributor.localId | A04129 | - |
dc.contributor.localId | A04777 | - |
dc.relation.journalcode | J02423 | - |
dc.identifier.eissn | 1423-0240 | - |
dc.identifier.pmid | 23689217 | - |
dc.identifier.url | http://www.karger.com/Article/FullText/350299 | - |
dc.subject.keyword | Rectal cancer | - |
dc.subject.keyword | Belly board | - |
dc.subject.keyword | Bladder compression device Small bowel | - |
dc.subject.keyword | Bladder | - |
dc.contributor.alternativeName | Keum, Ki Chang | - |
dc.contributor.alternativeName | Koom, Woong Sub | - |
dc.contributor.alternativeName | Nam, Ki Chang | - |
dc.contributor.alternativeName | Yoon, Hong In | - |
dc.contributor.alternativeName | Chung, Yoon Sun | - |
dc.contributor.alternativeName | Choi, Won Hoon | - |
dc.contributor.affiliatedAuthor | Keum, Ki Chang | - |
dc.contributor.affiliatedAuthor | Koom, Woong Sub | - |
dc.contributor.affiliatedAuthor | Nam, Ki Chang | - |
dc.contributor.affiliatedAuthor | Chung, Yoon Sun | - |
dc.contributor.affiliatedAuthor | Choi, Won Hoon | - |
dc.contributor.affiliatedAuthor | Yoon, Hong In | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 36 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 241 | - |
dc.citation.endPage | 246 | - |
dc.identifier.bibliographicCitation | ONKOLOGIE, Vol.36(5) : 241-246, 2013 | - |
dc.identifier.rimsid | 32031 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.