17 16

Cited 0 times in

Cited 0 times in

Automated dose-gradient curve and dose-volume histogram analysis platform: development, validation, and clinical decision support with TG-119 datasets

Authors
 Shin, Han-Back  ;  Cho, Wonyoung  ;  Choi, Young Eun  ;  Kim, Jin Sung  ;  Sung, KiHoon 
Citation
 FRONTIERS IN ONCOLOGY, Vol.16, 2026-05 
Article Number
 1826856 
Journal Title
FRONTIERS IN ONCOLOGY
Issue Date
2026-05
Keywords
dose fall-off ; dose gradient curve ; dose-volume histogram ; plan quality evaluation ; stereotactic radiotherapy
Abstract
Background Highly conformal radiotherapy techniques, such as stereotactic radiosurgery and stereotactic ablative radiotherapy, require steep dose fall-off to spare organs at risk (OARs). The dose-volume histogram (DVH) provides limited spatial information, whereas the dose gradient curve (DGC) offers quantitative assessment of dose fall-off but has seen limited clinical use due to time-consuming manual processing. Purpose This study aimed to develop and validate an automated DGC and DVH analysis platform to enable accurate and rapid dose gradient evaluation for radiotherapy plan assessment. Methods The platform automatically processes DICOM RT dose and RT structure files, with optional RT Plan input for direct prescription dose extraction, to compute differential and cumulative dose gradient index (dDGI and cDGI), DVH metrics, and clinically informed dose gradient quality grading. Computational validation was performed using AAPM TG-119 phantom datasets, including prostate, head and neck, C-shape, and multi-target cases, at 1.25 mm and 2.5 mm dose grid resolutions. Clinical validation was conducted using 142 Gamma Knife stereotactic radiosurgery plans for vestibular schwannoma from the publicly available Vestibular-Schwannoma-SEG dataset (The Cancer Imaging Archive). Results The platform reduced computation time from over 2 hours (original R-based workflow) to under 10 seconds, representing >99.8% efficiency improvement. All TG-119 cases met or exceeded recommended PTV coverage and OAR tolerances. Using prescription doses extracted from DICOM RT Plan file and marching-cubes-based surface area estimation, dDGI at the prescription dose ranged from 0.312 to 0.792 mm on the 1.25 mm grid and from 0.327 to 0.659 mm on the 2.5 mm grid; cDGI at 50% of the prescription dose ranged from 12.4 to 15.7 mm (1.25 mm) and from 11.7 to 15.5 mm (2.5 mm). Clinical validation with 142 vestibular schwannoma Gamma Knife SRS cases (median target volume 0.881 cc, range 0.036-7.183 cc; Rx = 12-13 Gy) yielded dDGI at Rx = 0.294 +/- 0.089 mm with Paddick conformity index = 0.584 +/- 0.075 and gradient index = 2.770 +/- 0.218. The dDGI was strongly correlated with target volume (Pearson r=0.885, p < 10(-48)) but independent of conformity index ( r=0.040, p = 0.634), confirming that gradient steepness and conformity assess distinct plan quality aspects. Paired T1-T2 MRI-based reproducibility analysis ( n=30) demonstrated excellent agreement (dDGI r=0.987, mean difference 3.3%). Conclusions The proposed platform enables rapid, automated DGC analysis practical for routine plan evaluation. The integrated quality grading bridges the gap between quantitative dose gradient metrics and actionable clinical decisions, complementing conventional DVH-based assessment.
Files in This Item:
94417.pdf Download
DOI
10.3389/fonc.2026.1826856
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jinsung(김진성) ORCID logo https://orcid.org/0000-0003-1415-6471
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/213043
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links