15 26

Cited 0 times in

Cited 0 times in

Fit analysis of 3D-printed versus thermoformed clear aligners for labial tooth movement using micro-CT: an in vitro study

Authors
 Lim, Sun Young  ;  Choi, Sung-Hwan  ;  Yu, Hyung-Seog  ;  Park, Sun-Hyung  ;  Kwon, Jae-Sung  ;  Kim, Su-Jung  ;  Liu, Jing  ;  Cha, Jung-Yul 
Citation
 SCIENTIFIC REPORTS, Vol.16(1), 2026-02 
Article Number
 7976 
Journal Title
SCIENTIFIC REPORTS
Issue Date
2026-02
MeSH
Humans ; Incisor / diagnostic imaging ; Printing, Three-Dimensional* ; Tooth Movement Techniques* / instrumentation ; Tooth Movement Techniques* / methods ; X-Ray Microtomography* / methods
Keywords
Activated tooth model ; 3D-printed clear aligner ; Thermoformed clear aligner ; Micro-CT ; fit ; Gap width
Abstract
This study examined the fit of 3D-printed and thermoformed clear aligners (CAs) on activated tooth models using micro-computed tomography (micro-CT). Three evaluation models were prepared: a passive model (P0.0) and two activated models (A0.3 and A0.5, where the upper right central incisor was labially displaced by 0.3 and 0.5 mm, respectively). Three CA material groups were tested: 3D-printed CAs made from TC-85 resin (3DP), thermoformed multi-layer CAs with a copolyester-elastomer combination (TM), and thermoformed single-layer CAs made of polyethylene terephthalate glycol (TS). CAs (n = 10) were fitted to corresponding models and scanned using micro-CT. Gap widths were measured at various tooth positions and measurement points in sagittal sections on all sides under passive and active states. Nonparametric analyses (Kruskal-Wallis tests with Bonferroni-corrected Mann-Whitney U post hoc comparisons) were performed with alpha = 0.05. The 3DP group exhibited significantly greater overall gap widths than the thermoformed groups (p < 0.001), with no significant effect of activation level (p = 0.350). In contrast, both the TM and TS groups showed significant increases in gap width with increasing activation (p < 0.001). Fit patterns differed by tooth position and measurement point, particularly in activated models, demonstrating distinct material-dependent adaptation behaviors.
Files in This Item:
92088.pdf Download
DOI
10.1038/s41598-026-37964-3
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실) > 1. Journal Papers
Yonsei Authors
Liu, Jing(Liu, Jing)
Kwon, Jae-Sung(권재성) ORCID logo https://orcid.org/0000-0001-9803-7730
Yu, Hyung Seog(유형석) ORCID logo https://orcid.org/0000-0002-1275-5078
Cha, Jung Yul(차정열)
Choi, Sung Hwan(최성환) ORCID logo https://orcid.org/0000-0002-1150-0268
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/211588
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links