0 20

Cited 0 times in

Cited 0 times in

Deep learning reconstruction for T2-weighted and contrast-enhanced T1-weighted magnetic resonance enterography imaging in patients with Crohn's disease: Assessment of image quality and clinical utility

Authors
 Cho, Choong-Wui  ;  You, Myung-Won  ;  Paek, Munyoung  ;  Nickel, Dominik  ;  Moon, Sung Kyoung 
Citation
 CLINICAL IMAGING, Vol.124, 2025-08 
Article Number
 110528 
Journal Title
CLINICAL IMAGING
ISSN
 0899-7071 
Issue Date
2025-08
Keywords
MR enterography ; Deep learning reconstruction ; Crohn&apos ; s disease ; Image quality ; T2-weighted image ; Half-Fourier single-shot turbo spin echo image
Abstract
Purpose: To investigate the image quality of deep learning-reconstructed T2-weighted half-Fourier single-shot turbo spin echo (DL T2 HASTE) and contrast-enhanced T1-weighted volumetric interpolated breath-hold examination (DL T1 VIBE) of magnetic resonance enterography in patients with Crohn's disease. Methods: Ninety-three patients for the comparison between T2 HASTE and DL T2 HASTE, and forty-two patients for the comparison between T1 VIBE and DL T1 VIBE were enrolled. Two reviewers assessed image quality using 5-point scale scoring, and subjective reviewer preferences. Acquisition times were also compared. The diagnostic performance for the detection of active inflammation was evaluated in three bowel segments (ileum, terminal ileum, and right colon). Results: The interobserver agreement on image quality was better for T2 HASTE (0.624, standard error 0.083), and T1 VIBE (0.53, SE 0.113) than for DL T2 HASTE (0.443, SE 0.111) and DL T1 VIBE (0.173, SE 0.153). The mean image quality scores showed no significant differences between T2 HASTE and DL T2 HASTE images, as well as between T1 VIBE and DL T1 VIBE images (p > 0.05). Both reviewers preferred T2 HASTE over DL T2 HASTE, although the preference between T1 VIBE and DL T1 VIBE was controversial. The acquisition times were shorter for DL T2 HASTE (16.17 +/- 2.53 s) and DL T1 VIBE (14.19 +/- 0.84 s) compared to T2 HASTE and T1 VIBE. The per-segment diagnostic performance for detecting active inflammation was identical between T2 HASTE and DL T2 HASTE. Conclusion: DL-reconstruction allows one-breath hold scan while maintaining image quality in both T2 HASTE and T1 VIBE images.
Full Text
https://www.sciencedirect.com/science/article/pii/S0899707125001287
DOI
10.1016/j.clinimag.2025.110528
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
You, Myung-Won(유명원)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/208298
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links