A preliminary study of super-resolution deep learning reconstruction with cardiac option for evaluation of endovascular-treated intracranial aneurysms

Authors
 Otgonbaatar, Chuluunbaatar  ;  Kim, Hyunjung  ;  Jeon, Pil-Hyun  ;  Jeon, Sang-Hyun  ;  Cha, Sung-Jin  ;  Ryu, Jae-Kyun  ;  Jung, Won Beom  ;  Shim, Hackjoon  ;  Ko, Sung Min  ;  Kim, Jin Woo 
Citation
 BRITISH JOURNAL OF RADIOLOGY, Vol.97(1160) : 1492-1500, 2024-06 
Journal Title
BRITISH JOURNAL OF RADIOLOGY
ISSN
 0007-1285 
Issue Date
2024-06
Keywords
intracranial aneurysm ; image reconstruction ; super-resolution deep learning reconstruction ; blooming artifact ; CT angiography
Abstract
Objectives: To investigate the usefulness of super-resolution deep learning reconstruction (SR-DLR) with cardiac option in the assessment of image quality in patients with stent-assisted coil embolization, coil embolization, and flow-diverting stent placement compared with other image reconstructions. Methods: This single-centre retrospective study included 50 patients (mean age, 59 years; range, 44-81 years; 13 men) who were treated with stent-assisted coil embolization, coil embolization, and flow-diverting stent placement between January and July 2023. The images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR), and SR-DLR. The objective image analysis included image noise in the Hounsfield unit (HU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and full width at half maximum (FWHM). Subjectively, two radiologists evaluated the overall image quality for the visualization of the flow-diverting stent, coil, and stent. Results: The image noise in HU in SR-DLR was 6.99 +/- 1.49, which was significantly lower than that in images reconstructed with FBP (12.32 +/- 3.01) and hybrid IR (8.63 +/- 2.12) (P < .001). Both the mean SNR and CNR were significantly higher in SR-DLR than in FBP and hybrid IR (P < .001 and P < .001). The FWHMs for the stent (P < .004), flow-diverting stent (P < .001), and coil (P < .001) were significantly lower in SR-DLR than in FBP and hybrid IR. The subjective visual scores were significantly higher in SR-DLR than in other image reconstructions (P < .001). Conclusions: SR-DLR with cardiac option is useful for follow-up imaging in stent-assisted coil embolization and flow-diverting stent placement in terms of lower image noise, higher SNR and CNR, superior subjective image analysis, and less blooming artifact than other image reconstructions. Advances in knowledge: SR-DLR with cardiac option allows better visualization of the peripheral and smaller cerebral arteries. SR-DLR with cardiac option can be beneficial for CT imaging of stent-assisted coil embolization and flow-diverting stent.
DOI
10.1093/bjr/tqae117
Appears in Collections:
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers
Yonsei Authors
Shim, Hack Joon(심학준)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/206564
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links