23 386

Cited 0 times in

Cited 0 times in

Artificial intelligence-based automated segmentation and radiotherapy dose mapping for thoracic normal tissues

DC Field Value Language
dc.contributor.authorJiang, Jue-
dc.contributor.authorChoi, Chloe Min Seo-
dc.contributor.authorDeasy, Joseph O.-
dc.contributor.authorRimner, Andreas-
dc.contributor.authorThor, Maria-
dc.contributor.authorVeeraraghavan, Harini-
dc.date.accessioned2025-07-09T08:35:41Z-
dc.date.available2025-07-09T08:35:41Z-
dc.date.created2025-03-31-
dc.date.issued2024-01-
dc.identifier.issn2405-6316-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/206510-
dc.description.abstractBackground and purpose: Objective assessment of delivered radiotherapy (RT) to thoracic organs requires fast and accurate deformable dose mapping. The aim of this study was to implement and evaluate an artificial intelligence (AI) deformable image registration (DIR) and organ segmentation-based AI dose mapping (AIDA) applied to the esophagus and the heart. Materials and methods: AIDA metrics were calculated for 72 locally advanced non-small cell lung cancer patients treated with concurrent chemo-RT to 60 Gy in 2 Gy fractions in an automated pipeline. The pipeline steps were: (i) automated rigid alignment and cropping of planning CT to week 1 and week 2 cone-beam CT (CBCT) field-ofviews, (ii) AI segmentation on CBCTs, and (iii) AI-DIR-based dose mapping to compute dose metrics. AIDA dose metrics were compared to the planned dose and manual contour dose mapping (manual DA). Results: AIDA required similar to 2 min/patient. Esophagus and heart segmentations were generated with a mean Dice similarity coefficient (DSC) of 0.80 +/- 0.15 and 0.94 +/- 0.05, a Hausdorff distance at 95th percentile (HD95) of 3.9 +/- 3.4 mm and 14.1 +/- 8.3 mm, respectively. AIDA heart dose was significantly lower than the planned heart dose (p = 0.04). Larger dose deviations (>=1Gy) were more frequently observed between AIDA and the planned dose (N = 26) than with manual DA (N = 6). Conclusions: Rapid estimation of RT dose to thoracic tissues from CBCT is feasible with AIDA. AIDA-derived metrics and segmentations were similar to manual DA, thus motivating the use of AIDA for RT applications.-
dc.description.statementOfResponsibilityopen-
dc.language영어-
dc.publisherELSEVIER-
dc.relation.isPartOfPHYSICS & IMAGING IN RADIATION ONCOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleArtificial intelligence-based automated segmentation and radiotherapy dose mapping for thoracic normal tissues-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorJiang, Jue-
dc.contributor.googleauthorChoi, Chloe Min Seo-
dc.contributor.googleauthorDeasy, Joseph O.-
dc.contributor.googleauthorRimner, Andreas-
dc.contributor.googleauthorThor, Maria-
dc.contributor.googleauthorVeeraraghavan, Harini-
dc.identifier.doi10.1016/j.phro.2024.100542-
dc.identifier.eissn2405-6316-
dc.identifier.pmid38369989-
dc.subject.keywordArtificial intelligence-
dc.subject.keywordRegistration-segmentation-
dc.subject.keywordAutomated dose mapping-
dc.subject.keywordLung cancer-
dc.subject.keywordCBCT-
dc.contributor.affiliatedAuthorChoi, Chloe Min Seo-
dc.identifier.scopusid2-s2.0-85185311525-
dc.identifier.wosid001186012800001-
dc.citation.volume29-
dc.identifier.bibliographicCitationPHYSICS & IMAGING IN RADIATION ONCOLOGY, Vol.29, 2024-01-
dc.identifier.rimsid86281-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorArtificial intelligence-
dc.subject.keywordAuthorRegistration-segmentation-
dc.subject.keywordAuthorAutomated dose mapping-
dc.subject.keywordAuthorLung cancer-
dc.subject.keywordAuthorCBCT-
dc.subject.keywordPlusDIFFEOMORPHIC IMAGE REGISTRATION-
dc.subject.keywordPlusLEARNING FRAMEWORK-
dc.subject.keywordPlusQUANTIFICATION-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryOncology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalResearchAreaOncology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.identifier.articleno100542-
Appears in Collections:
7. Others (기타) > Others (기타) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.