dc.description.abstractBackground: T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall. Purpose: To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis. Material and methods: This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated. Results: The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement. Conclusion: T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSage-
dc.relation.isPartOfACTA RADIOLOGICA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHCarotid Artery, Internal / diagnostic imaging-
dc.subject.MESHCarotid Stenosis* / diagnostic imaging-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImage Interpretation, Computer-Assisted / methods-
dc.subject.MESHMagnetic Resonance Angiography / methods-
dc.subject.MESHMagnetic Resonance Imaging / methods-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHProspective Studies-
dc.subject.MESHReproducibility of Results-
dc.titleReproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthorSo Yeon Won-
dc.contributor.googleauthorKijeong Lee-
dc.contributor.googleauthorIlah Shin-
dc.contributor.googleauthorHyun Seok Choi-
dc.contributor.googleauthorJai Ho Choi-
dc.contributor.googleauthorBum-Soo Kim-
dc.contributor.googleauthorYong Sam Shin-
dc.identifier.doi10.1177/02841851241268467-
dc.contributor.localIdA05848-
dc.contributor.localIdA05910-
dc.contributor.localIdA02696-
dc.contributor.localIdA04209-
dc.relation.journalcodeJ00033-
dc.identifier.eissn1600-0455-
dc.identifier.pmid39113532-
dc.identifier.urlhttps://journals.sagepub.com/doi/10.1177/02841851241268467-
dc.subject.keywordDANTE-SPACE-
dc.subject.keywordReproducibility-
dc.subject.keywordcarotid magnetic resonance imaging-
dc.subject.keywordcarotid wall segmentation-
dc.contributor.alternativeNameShin, Ilah-
dc.contributor.affiliatedAuthor신일아-
dc.contributor.affiliatedAuthor원소연-
dc.contributor.affiliatedAuthor이기정-
dc.contributor.affiliatedAuthor최현석-
dc.citation.volume65-
dc.citation.number10-
dc.citation.startPage1196-
dc.citation.endPage1204-
dc.identifier.bibliographicCitationACTA RADIOLOGICA, Vol.65(10) : 1196-1204, 2024-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.