Cited 0 times in
Cited 0 times in
Impact of clinical factors on the diagnostic performance of diffuse optical spectroscopic imaging for breast cancer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김민정 | - |
dc.contributor.author | 윤지영 | - |
dc.date.accessioned | 2025-06-27T02:44:19Z | - |
dc.date.available | 2025-06-27T02:44:19Z | - |
dc.date.issued | 2025-04 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/206041 | - |
dc.description.abstract | Due to insufficient sensitivity of mammography in dense breasts, ultrasonography and MRI have been incorporated into breast screening, despite increasing false positive risks. While optical imaging has been suggested to improve specificity, its effectiveness in diagnosing breast lesions remains unclear. This study investigates the impact of clinical factors on the diagnostic performance of diffuse optical spectroscopic imaging (DOSI) for detecting breast malignancies. Between March and May 2022, 62 women with 62 breast lesions (37 malignant, 25 benign) were analyzed using DOSI to quantify the concentrations of tissue chromophores (HbO2, HHb, water, lipid), total hemoglobin concentration (THC), oxygen saturation (StO2) and tissue optical index (TOI). The ratio of each parameter was compared to those of contralateral normal breasts, and diagnostic performance was assessed using area under the curve (AUC) values. The TOI ratio demonstrated the highest AUC (0.904, 95% CI 0.831-0.977), followed by water (0.836, 95% CI 0.736-0.936) and THC (0.738, 95% CI 0.613-0.864). The TOI ratio showed no significant differences in diagnostic performance based on clinical factors, whereas the water and THC ratios varied according to breast thickness, nipple distance, and BMI. Overall, the TOI ratio demonstrated strong diagnostic performance, suggesting its potential for universal application in breast cancer diagnosis. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Nature Publishing Group | - |
dc.relation.isPartOf | SCIENTIFIC REPORTS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Breast / diagnostic imaging | - |
dc.subject.MESH | Breast Neoplasms* / diagnostic imaging | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Mammography* / methods | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Republic of Korea | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Ultrasonography, Mammary | - |
dc.title | Impact of clinical factors on the diagnostic performance of diffuse optical spectroscopic imaging for breast cancer | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학교실) | - |
dc.contributor.googleauthor | Yeji Kwon | - |
dc.contributor.googleauthor | Jiyoung Yoon | - |
dc.contributor.googleauthor | Chanhui Lim | - |
dc.contributor.googleauthor | Heesun Hong | - |
dc.contributor.googleauthor | Sung-Ho Han | - |
dc.contributor.googleauthor | Min Jung Kim | - |
dc.identifier.doi | 10.1038/s41598-025-98519-6 | - |
dc.contributor.localId | A00473 | - |
dc.contributor.localId | A05730 | - |
dc.relation.journalcode | J02646 | - |
dc.identifier.eissn | 2045-2322 | - |
dc.identifier.pmid | 40281001 | - |
dc.contributor.alternativeName | Kim, Min Jung | - |
dc.contributor.affiliatedAuthor | 김민정 | - |
dc.contributor.affiliatedAuthor | 윤지영 | - |
dc.citation.volume | 15 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 14508 | - |
dc.identifier.bibliographicCitation | SCIENTIFIC REPORTS, Vol.15(1) : 14508, 2025-04 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.