Cited 0 times in

Framework for dual-energy-like chest radiography image synthesis from single-energy computed tomography based on cycle-consistent generative adversarial network

Authors
 Minjae Lee  ;  Hunwoo Lee  ;  Dongyeon Lee  ;  Hyosung Cho  ;  Jaegu Choi  ;  Bo Kyung Cha  ;  Kyuseok Kim 
Citation
 MEDICAL PHYSICS, Vol.51(2) : 1509-1530, 2024-02 
Journal Title
MEDICAL PHYSICS
ISSN
 0094-2405 
Issue Date
2024-02
MeSH
Artificial Intelligence* ; Image Processing, Computer-Assisted* / methods ; Radiography ; Thorax / diagnostic imaging ; Tomography, X-Ray Computed / methods
Keywords
chest X-ray radiographs ; deep learning ; dual-energy ; synthesized dual-energy imaging
Abstract
Background: Dual-energy (DE) chest radiography (CXR) enables the selective imaging of two relevant materials, namely, soft tissue and bone structures, to better characterize various chest pathologies (i.e., lung nodule, bony lesions, etc.) and potentially improve CXR-based diagnosis. Recently, deep-learning-based image synthesis techniques have attracted considerable attention as alternatives to existing DE methods (i.e., dual-exposure-based and sandwich-detector-based methods) because software-based bone-only and bone-suppression images in CXR could be useful.

Purpose: The objective of this study was to develop a new framework for DE-like CXR image synthesis from single-energy computed tomography (CT) based on a cycle-consistent generative adversarial network.

Methods: The core techniques of the proposed framework are divided into three categories: (1) data configuration from the generation of pseudo CXR from single energy CT, (2) learning of the developed network architecture using pseudo CXR and pseudo-DE imaging using a single-energy CT, and (3) inference of the trained network on real single-energy CXR. We performed a visual inspection and comparative evaluation using various metrics and introduced a figure of image quality (FIQ) to consider the effects of our framework on the spatial resolution and noise in terms of a single index through various test cases.

Results: Our results indicate that the proposed framework is effective and exhibits potential synthetic imaging ability for two relevant materials: soft tissue and bone structures. Its effectiveness was validated, and its ability to overcome the limitations associated with DE imaging techniques (e.g., increase in exposure dose owing to the requirement of two acquisitions, and emphasis on noise characteristics) via an artificial intelligence technique was presented.

Conclusions: The developed framework addresses X-ray dose issues in the field of radiation imaging and enables pseudo-DE imaging with single exposure.
Full Text
https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.16329
DOI
10.1002/mp.16329
Appears in Collections:
1. College of Medicine (의과대학) > Others (기타) > 1. Journal Papers
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/204188
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links