Cited 6 times in

Bioelectronic Sutures with Electrochemical pH-Sensing for Long-Term Monitoring of the Wound Healing Progress

Authors
 Hwajoong Kim  ;  Jung Hyun Kim  ;  Minji Jeong  ;  Dongwook Lee  ;  Jinho Kim  ;  Mugeun Lee  ;  Gain Kim  ;  Jayoung Kim  ;  Jung Seung Lee  ;  Jaehong Lee 
Citation
 ADVANCED FUNCTIONAL MATERIALS, Vol.34(40) : 2402501, 2024-10 
Journal Title
ADVANCED FUNCTIONAL MATERIALS
ISSN
 1616-301X 
Issue Date
2024-10
Abstract
The physiological pH level at wound sites is one of the fundamental factors for monitoring wound conditions in clinical practice. To continuously assess the wound conditions, a variety of bioelectronic pH sensors are extensively developed. However, despite significant advances in bioelectronics for wound monitoring, the application of existing bioelectronic devices, primarily designed as bandages or patches, remains challenging for monitoring pH levels in deep wounds. Here, a flexible pH-sensing suture is introduced that can be simultaneously used as both a precise pH sensor for wound monitoring and a conventional medical suture. The electrochemical pH-sensing suture comprises Au nanoparticle-based flexible electrodes functionalized with polyaniline for the working electrode and Ag/AgCl for the reference electrode, seamlessly integrated onto a standard medical suturing thread. This dual-function sensing suture offers a reliable and high sensitivity of 58.9 mV pH-1, negligible hysteresis, high stability, and excellent selectivity in pH sensing. The biocompatibility of the sensing suture is systematically verified for its in vivo use. To demonstrate the capabilities of the pH-sensing suture, it is successfully applied to an incision and chronic wound model of mouse to perform continuous and accurate monitoring of the inflammation and healing progress of the wound throughout the healing period.,An innovative pH-sensing suture, with dual functions as a precise pH sensor and a conventional surgical suture, performs continuous and accurate monitoring of inflammation and healing progress throughout the healing period. It features high stability, negligible hysteresis, and excellent selectivity for pH sensing. The study includes demonstrations using a natural incision and chronic wound model in an in vivo mouse. image,
Full Text
https://onlinelibrary.wiley.com/doi/10.1002/adfm.202402501
DOI
10.1002/adfm.202402501
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jayoung(김자영)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/200992
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links