Cited 0 times in

Impact of Respiratory Motion on the Quantification of Pediatric Hepatic Steatosis Using Two Different Ultrasonography Machines

DC Field Value Language
dc.contributor.author송경철-
dc.contributor.author신현주-
dc.contributor.author한경화-
dc.contributor.author황신혜-
dc.date.accessioned2024-12-06T01:51:41Z-
dc.date.available2024-12-06T01:51:41Z-
dc.date.issued2024-10-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/200621-
dc.description.abstractPurpose This study aimed to investigate the effect of respiratory motion on hepatic steatosis quantification using ultrasound attenuation imaging (ATI) or ultrasound-guided attenuation parameter (UGAP) in pediatric patients. Materials and Methods Pediatric patients (aged ≤18 years) who underwent liver ultrasonography (US) with ATI or UGAP between May 2022 and February 2023 were included retrospectively. Median, interquartile range (IQR), and IQR/median values were calculated in both free-breathing (FB) and breath-holding (BH) states. Subjects were divided into normal and fatty liver groups according to grayscale US. Wilcoxon signed rank test, intraclass correlation coefficient (ICC), and linear regression test were used. Results A total of 83 patients (M:F=46:37, median age 10 years, range 6–17 years) was included, with 55 patients in the ATI group and 28 patients in the UGAP group. The measured values of ATI and UGAP were not significantly different between FB and BH. The ICC values between FB and BH states were 0.950 [95% confidence interval (CI) 0.916–0.971] for median ATI and 0.786 (95% CI 0.591–0.894) for median UGAP. FB and BH status did not significantly affect the median ATI and UGAP (p=0.852, 0.531, respectively). The IQR/median value showed a significant association with age only in the FB status of the normal group using ATI (β= -0.014, p=0.042). Conclusion Respiratory motion does not significantly affect the measurement of ATI or UGAP. Median ATI value showed excellent agreement in FB and BH status, while UGAP showed good agreement. Younger age may affect measurement variability in FB status of the normal group using ATI.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAdolescent-
dc.subject.MESHChild-
dc.subject.MESHFatty Liver* / diagnostic imaging-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLiver / diagnostic imaging-
dc.subject.MESHMale-
dc.subject.MESHRespiration-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHUltrasonography* / methods-
dc.titleImpact of Respiratory Motion on the Quantification of Pediatric Hepatic Steatosis Using Two Different Ultrasonography Machines-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Pediatrics (소아과학교실)-
dc.contributor.googleauthorHyun Joo Shin-
dc.contributor.googleauthorKyungchul Song-
dc.contributor.googleauthorSinhye Hwang-
dc.contributor.googleauthorKyunghwa Han-
dc.contributor.googleauthorLeeha Ryu-
dc.identifier.doi10.3349/ymj.2023.0440-
dc.contributor.localIdA06013-
dc.contributor.localIdA02178-
dc.contributor.localIdA04267-
dc.contributor.localIdA05534-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid39313451-
dc.subject.keywordChild-
dc.subject.keyworddiagnostic imaging-
dc.subject.keywordfatty liver-
dc.subject.keywordretrospective study-
dc.subject.keywordultrasonography-
dc.contributor.alternativeNameSong, Kyungchul-
dc.contributor.affiliatedAuthor송경철-
dc.contributor.affiliatedAuthor신현주-
dc.contributor.affiliatedAuthor한경화-
dc.contributor.affiliatedAuthor황신혜-
dc.citation.volume65-
dc.citation.number10-
dc.citation.startPage602-
dc.citation.endPage610-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.65(10) : 602-610, 2024-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pediatrics (소아과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.