Cited 4 times in
Evaluation of the effects of temperature and centrifugation time on elimination of uncured resin from 3D-printed dental aligners
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 권재성 | - |
dc.contributor.author | 이기준 | - |
dc.contributor.author | 차정열 | - |
dc.contributor.author | 최성환 | - |
dc.contributor.author | 만갈웃커시 | - |
dc.date.accessioned | 2024-08-19T00:13:55Z | - |
dc.date.available | 2024-08-19T00:13:55Z | - |
dc.date.issued | 2024-07 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/200261 | - |
dc.description.abstract | The study investigated the effects of temperature and centrifugation time on the efficacy of removing uncured resin from 3D-printed clear aligners. Using a photo-polymerizable polyurethane resin (Tera Harz TC-85, Graphy Inc., Seoul, Korea), aligners were printed and subjected to cleaning processes using isopropyl alcohol (IPA) or centrifugation (g-force 27.95g) at room temperature (RT, 23 °C) and high temperature (HT, 55 °C) for 2, 4, and 6 min. The control group received no treatment (NT). Cleaning efficiency was assessed through rheological analysis, weight measurement, transparency evaluation, SEM imaging, 3D geometry evaluation, stress relaxation, and cell viability tests. Results showed increased temperature and longer centrifugation times significantly reduced aligner viscosity, weight (P < 0.05), and transmittance. IPA-cleaned aligners exhibited significantly lower transparency and rougher surfaces in SEM images. All groups met ISO biocompatibility standards in cytotoxicity tests. The NT group had higher root mean square (RMS) values, indicating greater deviation from the original design. Stress relaxation tests revealed over 95% recovery in all groups after 60 min. The findings suggest that a 2-min HT centrifugation process effectively removes uncured resin without significantly impacting the aligners' physical and optical properties, making it a clinically viable option. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English | - |
dc.publisher | Nature Publishing Group | - |
dc.relation.isPartOf | SCIENTIFIC REPORTS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Animals | - |
dc.subject.MESH | Cell Survival / drug effects | - |
dc.subject.MESH | Centrifugation* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Materials Testing | - |
dc.subject.MESH | Polyurethanes / chemistry | - |
dc.subject.MESH | Printing, Three-Dimensional* | - |
dc.subject.MESH | Resins, Synthetic / chemistry | - |
dc.subject.MESH | Temperature* | - |
dc.title | Evaluation of the effects of temperature and centrifugation time on elimination of uncured resin from 3D-printed dental aligners | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실) | - |
dc.contributor.googleauthor | Ji-Eun Kim | - |
dc.contributor.googleauthor | Utkarsh Mangal | - |
dc.contributor.googleauthor | Jae-Hun Yu | - |
dc.contributor.googleauthor | Gi-Tae Kim | - |
dc.contributor.googleauthor | Hoon Kim | - |
dc.contributor.googleauthor | Ji-Young Seo | - |
dc.contributor.googleauthor | Jung-Yul Cha | - |
dc.contributor.googleauthor | Kee-Joon Lee | - |
dc.contributor.googleauthor | Jae-Sung Kwon | - |
dc.contributor.googleauthor | Sung-Hwan Choi | - |
dc.identifier.doi | 10.1038/s41598-024-66150-6 | - |
dc.contributor.localId | A00247 | - |
dc.contributor.localId | A02698 | - |
dc.contributor.localId | A04006 | - |
dc.contributor.localId | A04083 | - |
dc.relation.journalcode | J02646 | - |
dc.identifier.eissn | 2045-2322 | - |
dc.identifier.pmid | 38956329 | - |
dc.subject.keyword | 3D printing | - |
dc.subject.keyword | Centrifugation | - |
dc.subject.keyword | Clear aligner | - |
dc.subject.keyword | Cytocompatibility | - |
dc.subject.keyword | Translucency | - |
dc.subject.keyword | Uncured resin | - |
dc.contributor.alternativeName | Kwon, Jae-Sung | - |
dc.contributor.affiliatedAuthor | 권재성 | - |
dc.contributor.affiliatedAuthor | 이기준 | - |
dc.contributor.affiliatedAuthor | 차정열 | - |
dc.contributor.affiliatedAuthor | 최성환 | - |
dc.citation.volume | 14 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 15206 | - |
dc.identifier.bibliographicCitation | SCIENTIFIC REPORTS, Vol.14(1) : 15206, 2024-07 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.