Cited 0 times in

Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis

Authors
 Ji Soo Choi  ;  Se Hyun Kwak  ;  Min Chul Kim  ;  Chang Hwan Seol  ;  Seok-Jae Heo  ;  Sung Ryeol Kim  ;  Eun Hye Lee 
Citation
 ULTRASOUND QUARTERLY, Vol.87(3) : 368-377, 2024-07 
Journal Title
ULTRASOUND QUARTERLY
ISSN
 0894-8771 
Issue Date
2024-07
Keywords
Bronchiectasis ; Disease Severity ; Impulse Oscillometry
Abstract
Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis.

Methods: We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups.

Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 ≥0.43, resistance at 20 Hz (R20) ≥0.234, R5-R20 ≥28.3, AX ≥1.02, reactance at 5 Hz (X5) ≤-0.238, and Fres ≥20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 ≤-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate- to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809.

Conclusion: The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable tools for predicting bronchiectasis severity.
Files in This Item:
T202403524.pdf Download
DOI
10.4046/trd.2023.0160
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Dong Kyu(김동규) ORCID logo https://orcid.org/0000-0001-7322-2550
Choi, Ji Soo(최지수) ORCID logo https://orcid.org/0000-0003-2716-6775
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/200170
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links