0 17

Cited 0 times in

Maximal detrusor pressure can be predicted using technetium-99m-mertcaptoacetyltriglycine renal scintigraphy in the early stages of spinal cord injury

Authors
 Su Ji Lee  ;  Ji Cheol Shin 
Citation
 SPINAL CORD, Vol.62(5) : 207-213, 2024-05 
Journal Title
SPINAL CORD
ISSN
 1362-4393 
Issue Date
2024-05
MeSH
Adult ; Aged ; Female ; Humans ; Kidney / diagnostic imaging ; Kidney / physiopathology ; Male ; Middle Aged ; Radionuclide Imaging ; Radiopharmaceuticals ; Retrospective Studies ; Spinal Cord Injuries* / complications ; Spinal Cord Injuries* / diagnostic imaging ; Spinal Cord Injuries* / physiopathology ; Technetium Tc 99m Mertiatide* ; Urinary Bladder / diagnostic imaging ; Urinary Bladder / physiopathology ; Urinary Bladder, Neurogenic / diagnostic imaging ; Urinary Bladder, Neurogenic / etiology ; Urinary Bladder, Neurogenic / physiopathology ; Urodynamics* / physiology
Abstract
Study design: Retrospective cohort study.

Objective: To investigate the potential of technetium-99m-mercaptoacetyltriglycine (99mTc-MAG-3) renal scintigraphy for predicting maximal detrusor pressure in the early stages of spinal cord injury (SCI).

Setting: Tertiary rehabilitation facility.

Methods: Medical records of individuals with SCI admitted between January 2020 and April 2023 who underwent both 99mTc-MAG-3 renal scintigraphy and urodynamic study within 90 days of SCI onset were retrospectively reviewed. Pearson's coefficient analysis was performed to determine the relationship between 99mTc-MAG-3 renal scintigraphy findings and urodynamic study findings. A multivariate linear regression analysis was performed to determine the best predictors of maximal detrusor pressure. A multivariate logistic regression analysis was performed to determine risk factors for high detrusor pressure.

Results: Ninety-four participants were enrolled in this study. Pearson's correlation analysis showed that effective renal plasma flow (ERPF) and ERPF (% predicted) were significantly correlated with maximal detrusor pressure. The multivariate linear regression analysis demonstrated that ERPF (% predicted) was a significant predictor of maximal detrusor pressure. The multivariate logistic regression analysis showed that ERPF (% predicted) was significantly associated with high detrusor pressure. The receiver operating characteristic curve demonstrated that the predictive model had an area under the curve of 0.725, with an ERPF (% predicted) cut-off of 64.05%, sensitivity 1.000, and specificity 0.429.

Conclusions: These results suggest that 99mTc-MAG-3 renal scintigraphy may be useful for predicting high detrusor pressure in early SCI and may guide the timing of urodynamic studies in individuals with early SCI for appropriate management of neurogenic lower urinary tract dysfunction.
Full Text
https://www.nature.com/articles/s41393-024-00967-w
DOI
10.1038/s41393-024-00967-w
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Rehabilitation Medicine (재활의학교실) > 1. Journal Papers
Yonsei Authors
Shin, Ji Cheol(신지철) ORCID logo https://orcid.org/0000-0002-1133-1361
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/200075
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links