14 47

Cited 0 times in

The effectiveness of post-processing head and neck CT angiography using contrast enhancement boost technique

Authors
 Chuluunbaatar Otgonbaatar  ;  Pil-Hyun Jeon  ;  Jae-Kyun Ryu  ;  Hackjoon Shim  ;  Sang-Hyun Jeon  ;  Sung Min Ko  ;  Hyunjung Kim  ;  Jin Woo Kim 
Citation
 PLOS ONE, Vol.18(4) : e0284793, 2023-04 
Journal Title
PLOS ONE
Issue Date
2023-04
MeSH
Aged ; Angiography ; Computed Tomography Angiography* / methods ; Contrast Media* ; Female ; Head / diagnostic imaging ; Humans ; Middle Aged ; Radiographic Image Interpretation, Computer-Assisted / methods ; Retrospective Studies ; Signal-To-Noise Ratio ; Tomography, X-Ray Computed / methods
Abstract
Background and purposeThis study aimed to investigate the potential of contrast enhancement (CE)-boost technique in the head and neck computed tomography (CT) angiography in terms of the objective and subjective image quality. Materials and methodsConsecutive patients who underwent head and neck CT angiography between May 2022 and July 2022 were included. The CE-boost images were generated by combining the subtracted iodinated image and contrast-enhanced image. The objective image analysis was compared for each image with and without CE-boost technique using the CT attenuation, image noise, signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), and image sharpness (full width at half width maximum, FWHM). The subjective image analysis was evaluated by two independent experienced radiologists in the following aspects: the overall image quality, motion artifact, vascular delineation, and vessel sharpness. ResultsA total of 65 patients (mean age, 59.48 +/- 13.71 years; range, 24-87 years; 36 women) were included. The CT attenuation of the vertebrobasilar arteries was significantly (p < 0.001) higher in the images obtained using CE-boost technique than in conventional images. Image noise was significantly (p < 0.001) lower for CE-boost images (6.09 +/- 1.93) than for conventional images (7.79 +/- 1.73). Moreover, CE-boost technique yielded higher SNR (64.43 +/- 17.17 vs. 121.37 +/- 38.77, p < 0.001) and CNR (56.90 +/- 18.79 vs. 116.65 +/- 57.44, p < 0.001) than conventional images. CE-boost resulted in shorter FWHM than conventional images (p < 0.001). Higher subjective image quality scores were also demonstrated by the CE-boost than images without CE-boost technique. ConclusionsIn both objective and subjective image analysis, the CE-boost technique provided higher image quality without increasing the flow rate and concentration of contrast media in the head and neck CT angiography. Furthermore, the vessel completeness and delineation were superior in CE-boost images than in conventional images.
Files in This Item:
T992023335.pdf Download
DOI
10.1371/journal.pone.0284793
Appears in Collections:
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers
Yonsei Authors
Shim, Hack Joon(심학준)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/199600
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links