Deep learning proton beam range estimation model for quality assurance based on two-dimensional scintillated light distributions in simulations

Authors
 Eunho Lee  ;  Byungchul Cho  ;  Jungwon Kwak  ;  Chiyoung Jeong  ;  Min-Jae Park  ;  Sung-Woo Kim  ;  Si Yeol Song  ;  Youngmoon Goh 
Citation
 MEDICAL PHYSICS, Vol.50(11) : 7203-7213, 2023-11 
Journal Title
MEDICAL PHYSICS
ISSN
 0094-2405 
Issue Date
2023-11
MeSH
Computer Simulation ; Deep Learning* ; Monte Carlo Method ; Proton Therapy* / methods ; Protons ; Radiotherapy Dosage ; Water
Keywords
Bragg peak ; Monte Carlo simulation ; deep learning ; residual U-net ; scintillation
Abstract
BackgroundMany studies have utilized optical camera systems with volumetric scintillators for quality assurances (QA) to estimate the proton beam range. However, previous analytically driven range estimation methods have the difficulty to derive the dose distributions from the scintillation images with quenching and optical effects. PurposeIn this study, a deep learning method utilized to QA was used to predict the beam range and spread-out Bragg peak (SOBP) for two-dimensional (2D) map conversion from the scintillation light distribution (LD) into the dose distribution in a water phantom. MethodsThe 2D residual U-net modeling for deep learning was used to predict the 2D water dose map from a 2D scintillation LD map. Monte Carlo simulations for dataset preparation were performed with varying monoenergetic proton beam energies, field sizes, and beam axis shifts. The LD was reconstructed using photons backpropagated from the aperture as a virtual lens. The SOBP samples were constructed based on monoenergetic dose distributions. The training set, including the validation set, consisted of 8659 image pairs of LD and water dose maps. After training, dose map prediction was performed using a 300 image pair test set generated under random conditions. The pairs of simulated and predicted dose maps were analyzed by Bragg peak fitting and gamma index maps to evaluate the model prediction. ResultThe estimated beam range and SOBP width resolutions were 0.02 and 0.19 mm respectively for varying beam conditions, and the beam range and SOBP width deviations from the reference simulation result were less than 0.1 and 0.8 mm respectively. The simulated and predicted distributions showed good agreement in the gamma analysis, except for rare cases with failed gamma indices in the proximal and field-marginal regions. ConclusionThe deep learning conversion method using scintillation LDs in an optical camera system with a scintillator is feasible for estimating proton beam range and SOBP width with high accuracy.
Full Text
https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.16646
DOI
10.1002/mp.16646
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/199332
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links