43 107

Cited 0 times in

Attributes of errors, facilitators, and barriers related to rate control of IV medications: a scoping review

Authors
 Jeongok Park  ;  Sang Bin You  ;  Gi Wook Ryu  ;  Youngkyung Kim 
Citation
 SYSTEMATIC REVIEWS, Vol.12(1) : 230, 2023-12 
Journal Title
SYSTEMATIC REVIEWS
Issue Date
2023-12
MeSH
Delivery of Health Care ; Health Personnel* / education ; Humans ; Medication Errors* / prevention & control ; Prospective Studie
Keywords
Medication safety ; Nurses ; Patient safety ; Quality improvement ; Safety culture
Abstract
Background: Intravenous (IV) medication is commonly administered and closely associated with patient safety. Although nurses dedicate considerable time and effort to rate the control of IV medications, many medication errors have been linked to the wrong rate of IV medication. Further, there is a lack of comprehensive studies examining the literature on rate control of IV medications. This study aimed to identify the attributes of errors, facilitators, and barriers related to rate control of IV medications by summarizing and synthesizing the existing literature. Methods: This scoping review was conducted using the framework proposed by Arksey and O’Malley and PRISMA-ScR. Overall, four databases—PubMed, Web of Science, EMBASE, and CINAHL—were employed to search for studies published in English before January 2023. We also manually searched reference lists, related journals, and Google Scholar. Results: A total of 1211 studies were retrieved from the database searches and 23 studies were identified from manual searches, after which 22 studies were selected for the analysis. Among the nine project or experiment studies, two interventions were effective in decreasing errors related to rate control of IV medications. One of them was prospective, continuous incident reporting followed by prevention strategies, and the other encompassed six interventions to mitigate interruptions in medication verification and administration. Facilitators and barriers related to rate control of IV medications were classified as human, design, and system-related contributing factors. The sub-categories of human factors were classified as knowledge deficit, performance deficit, and incorrect dosage or infusion rate. The sub-category of design factor was device. The system-related contributing factors were classified as frequent interruptions and distractions, training, assignment or placement of healthcare providers (HCPs) or inexperienced personnel, policies and procedures, and communication systems between HCPs. Conclusions: Further research is needed to develop effective interventions to improve IV rate control. Considering the rapid growth of technology in medical settings, interventions and policy changes regarding education and the work environment are necessary. Additionally, each key group such as HCPs, healthcare administrators, and engineers specializing in IV medication infusion devices should perform its role and cooperate for appropriate IV rate control within a structured system. © 2023, The Author(s).
Files in This Item:
T202400808.pdf Download
DOI
10.1186/s13643-023-02386-z
Appears in Collections:
3. College of Nursing (간호대학) > Dept. of Nursing (간호학과) > 1. Journal Papers
Yonsei Authors
Park, Jeongok(박정옥) ORCID logo https://orcid.org/0000-0003-4978-817X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/198032
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links