71 191

Cited 9 times in

Analysis of the causes of recurrence after frontalis suspension using silicone rods for congenital ptosis

Authors
 Chang Yeom Kim  ;  Byeong Jae Son  ;  Jangyup Son  ;  Jongill Hong  ;  Sang Yeul Lee 
Citation
 PLOS ONE, Vol.12(2) : e0171769, 2017-02 
Journal Title
PLOS ONE
Issue Date
2017-02
MeSH
Biocompatible Materials / adverse effects* ; Blepharoptosis / congenital ; Blepharoptosis / pathology* ; Blepharoptosis / surgery ; Child, Preschool ; Female ; Humans ; Infant ; Male ; Materials Testing ; Prospective Studies ; Prostheses and Implants / adverse effects* ; Recurrence ; Silicones*
Abstract
Background: Silicone rod is a commonly used synthetic suspension material in frontalis suspension surgery to correct blepharoptosis. The most challenging problem and a decisive drawback of the use of silicone rod is a considerable rate of ptosis recurrence after surgery. We examined patients with recurred ptosis and assessed the physical and micromorphological properties of implanted silicone rods to determine the causative mechanisms of recurred ptosis after frontalis suspension using silicone rod.

Methods: This is a prospective observational case series of 22 pediatric patients with recurred ptosis after frontalis suspension using silicone rods for congenital ptosis. Implanted silicone rods were observed and removed during the operation for correction of recurred ptosis. The removed silicone rods were physically and micromorphologically evaluated to determine the cause of recurrence.

Results: Pretarsal fixation positions migrated upward, whereas suprabrow fixation positions migrated downward during ptosis recurrence. The breaking strength of implanted silicone rods was reduced by approximately 50% during 3 years. Cracks, debris, and loss of homogenous structure with disintegration were observed on scanning electron micrographs of implanted silicone rods in patients with recurred ptosis. Preoperative severe degree of ptosis also contributed to recurred ptosis.

Conclusions: Recurrence of ptosis after frontalis suspension using silicone rod was associated with physical changes of implanted silicone rods, including positional migration, weakened tensile strength, and micromorphological changes in combination with patients' characteristics.
Files in This Item:
T999201763.pdf Download
DOI
10.1371/journal.pone.0171769
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Chang Yeom(김창염)
Lee, Sang Yeul(이상열)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/195870
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links