0 131

Cited 23 times in

Immunosensor Employing Stable, Solid 1-Amino-2-naphthyl Phosphate and Ammonia-Borane toward Ultrasensitive and Simple Point-of-Care Testing

Authors
 Jeongwook Seo  ;  Hyeri Ha  ;  Seonhwa Park  ;  Al-Monsur Jiaul Haque  ;  Sinyoung Kim  ;  Jung Min Joo  ;  Haesik Yang 
Citation
 ACS SENSORS, Vol.2(8) : 1240-1246, 2017-08 
Journal Title
ACS SENSORS
ISSN
 2379-3694 
Issue Date
2017-08
Keywords
ITO electrode ; alkaline phosphatase ; biosensor ; electrochemical immunosensor ; point-of-care testing ; redox cycling.
Abstract
Biosensors for ultrasensitive point-of-care testing require dried reagents with long-term stability and a high signal-to-background ratio. Although ortho-substituted diaromatic dihydroxy and aminohydroxy compounds undergo fast redox reactions, they are not used as electrochemical signaling species because they are readily oxidized and polymerized by dissolved oxygen. In this report, stable, solid 1-amino-2-naphthyl phosphate (1A2N-P) and ammonia-borane (H3N-BH3) are respectively employed as a substrate for alkaline phosphatase (ALP) and a reductant for electrochemical-chemical (EC) redox cycling. ALP converts 1A2N-P to 1-amino-2-naphthol (1A2N), which is then employed in EC redox cycling using H3N-BH3. The oxidation and polymerization of 1A2N by dissolved oxygen is significantly prevented in the presence of H3N-BH3. The electrochemical measurement is performed without modification of indium-tin oxide (ITO) electrodes with electrocatalytic materials. For comparison, nine aromatic dihydroxy and aminohydroxy compounds, including 1A2N, are evaluated to achieve fast EC redox cycling, and four strong reductants, including H3N-BH3, are evaluated to achieve a low background level. The combination of 1A2N and H3N-BH3 allows the achievement of a very high signal-to-background ratio. When the newly developed combination is applied to the detection of creatine kinase-MB (CK-MB), the detection limit for CK-MB is ∼80 fg/mL, indicating that the combination allows ultrasensitive detection. The concentrations of CK-MB in clinical serum samples, determined using the developed system, are in good agreement with the concentrations obtained using a commercial instrument. Thus, the use of stable, solid 1A2N-P and H3N-BH3 along with bare ITO electrodes is highly promising for ultrasensitive and simple point-of-care testing.
Full Text
https://pubs.acs.org/doi/10.1021/acssensors.7b00407
DOI
10.1021/acssensors.7b00407
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sin Young(김신영) ORCID logo https://orcid.org/0000-0002-2609-8945
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/195598