172 306

Cited 0 times in

Cited 0 times in

Effect of Outlier Elimination on the 99th Percentile Upper Reference Limits of High-Sensitivity Cardiac Troponin I Assays Based on a Strictly Selected Healthy Reference Population

DC Field Value Language
dc.contributor.authorAHN, SUNYOUNG-
dc.contributor.authorKim, Hyun-Ki-
dc.contributor.authorLee, Woochang-
dc.contributor.authorChun, Sail-
dc.contributor.authorMin, Won-Ki-
dc.date.accessioned2023-06-02T00:50:25Z-
dc.date.available2023-06-02T00:50:25Z-
dc.date.created2023-03-30-
dc.date.issued2022-05-
dc.identifier.issn2234-3806-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/194466-
dc.description.abstractBackground: We established high-sensitivity cardiac troponin I (hsTnI) 99th percentile upper reference limits (URLs) for the Centaur XPT High-Sensitivity Troponin I assay (Centaur hsTnI; Siemens, Erlangen, Germany) and Atellica IM High-Sensitivity Troponin I assay (Atellica hsTnI; Siemens) and assessed the effect of outlier elimination. Methods: The reference population comprised 380 men and 387 women, satisfying the strict systematic reference population criteria. After reference population verification by the N-terminal pro-B-type natriuretic peptide (NT-proBNP) assay, 99th percentile URLs for Centaur hsTnI and Atellica hsTnI were calculated before and after outlier elimination. Results: The 99th percentile URL for Centaur hsTnI was 60.4 (men, 74.7; women, 57.5) ng/L and that for Atellica hsTnI was 59.6 (men, 75.2; women, 55.1) ng/L. After the elimination of 61 (8.0%) outlier samples in Centaur hsTnI and 58 (7.6%) in Atellica hsTnI, the 99th percentile URLs were 13.5 ng/L (men, 15.3 ng/L; women, 11.9 ng/L) and 13.4 ng/L (men, 15.5 ng/L; women, 12.9 ng/L), respectively, significantly lower than those before outlier elimination. The CVs at the 99th percentile URLs were 5.2% and 3.5%, respectively. The measurable fractions among the reference population were 91.5% and 93.4%, respectively. Performance evaluation of Atellica B-type natriuretic peptide (BNP), Atellica NT-proBNP, Centaur hsTnI, and Atellica hsTnI showed outstanding results. Conclusions: The Korean hsTnI 99th percentile URLs calculated in this study were significantly lower after outlier elimination than before. Centaur hsTnI and Atellica hsTnI meet the "Guideline acceptable" and "Level 3 (second generation, high sensitivity)" requirements, satisfying international standards.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfAnnals of Laboratory Medicine-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEffect of Outlier Elimination on the 99th Percentile Upper Reference Limits of High-Sensitivity Cardiac Troponin I Assays Based on a Strictly Selected Healthy Reference Population-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorAHN, SUNYOUNG-
dc.contributor.googleauthorKim, Hyun-Ki-
dc.contributor.googleauthorLee, Woochang-
dc.contributor.googleauthorChun, Sail-
dc.contributor.googleauthorMin, Won-Ki-
dc.identifier.doi10.3343/alm.2022.42.3.331-
dc.relation.journalcodeJ00164-
dc.identifier.eissn2234-3814-
dc.identifier.pmid34907103-
dc.subject.keywordKey Words-
dc.subject.keywordNinety-ninth percentile-
dc.subject.keywordUpper reference limit-
dc.subject.keywordKorean-
dc.subject.keywordOutlier-
dc.subject.keywordADVIA Centaur XPT High-Sensitivity Troponin I assay-
dc.subject.keywordAtellica IM High-Sensitivity Troponin I assay-
dc.contributor.affiliatedAuthorAHN, SUNYOUNG-
dc.identifier.scopusid2-s2.0-85122616904-
dc.identifier.wosid000737636900005-
dc.citation.volume42-
dc.citation.number3-
dc.citation.startPage331-
dc.citation.endPage341-
dc.identifier.bibliographicCitationAnnals of Laboratory Medicine, Vol.42(3) : 331-341, 2022-05-
dc.identifier.rimsid78307-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorKey Words-
dc.subject.keywordAuthorNinety-ninth percentile-
dc.subject.keywordAuthorUpper reference limit-
dc.subject.keywordAuthorKorean-
dc.subject.keywordAuthorOutlier-
dc.subject.keywordAuthorADVIA Centaur XPT High-Sensitivity Troponin I assay-
dc.subject.keywordAuthorAtellica IM High-Sensitivity Troponin I assay-
dc.subject.keywordPlusMYOCARDIAL-INFARCTION-
dc.subject.keywordPlusSEX-
dc.subject.keywordPlusAGE-
dc.type.docTypeArticle-
dc.identifier.kciidART002832430-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.relation.journalResearchAreaMedical Laboratory Technology-
Appears in Collections:
7. Others (기타) > Others (기타) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.