Cited 5 times in
Phantom-based correction for standardization of myocardial native T1 and extracellular volume fraction in healthy subjects at 3-Tesla cardiac magnetic resonance imaging
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서영주 | - |
dc.contributor.author | 최병욱 | - |
dc.date.accessioned | 2023-03-03T02:19:17Z | - |
dc.date.available | 2023-03-03T02:19:17Z | - |
dc.date.issued | 2022-12 | - |
dc.identifier.issn | 0938-7994 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/192799 | - |
dc.description.abstract | Objectives: To investigate the effect of the phantom-based correction method for standardizing myocardial native T1 and extracellular volume fraction (ECV) in healthy subjects. Methods: Seventy-one healthy asymptomatic adult (≥ 20 years) volunteers of five different age groups (34 men and 37 women, 45.5 ± 15.5 years) were prospectively enrolled in three academic hospitals. Cardiac MRI including Modified Look - Locker Inversion recovery T1 mapping sequence was performed using a 3-Tesla system with a different type of scanner for each hospital. Native T1 and ECV were measured in the short-axis T1 map and analyzed for mean values of the 16 entire segments. The myocardial T1 value of each subject was corrected based on the site-specific equation derived from the T1 Mapping and ECV Standardization phantom. The global native T1 and ECV were compared between institutions before and after phantom-based correction, and the variation in native T1 and ECV among institutions was assessed using a coefficient of variation (CoV). Results: The global native T1 value significantly differed between the institutions (1198.7 ± 32.1 ms, institution A; 1217.7 ± 39.9 ms, institution B; 1232.7 ± 31.1 ms, institution C; p = 0.002), but the mean ECV did not (26.6-27.5%, p = 0.355). After phantom-based correction, the global native T1 and ECV were 1289.7 ± 32.4 ms and 25.0 ± 2.7%, respectively, and CoV for native T1 between the three institutions decreased from 3.0 to 2.5%. The corrected native T1 value did not significantly differ between institutions (1284.5 ± 31.5 ms, institution A; 1296.5 ± 39.1 ms, institution B; 1291.3 ± 29.3 ms, institution C; p = 0.440), and neither did the ECV (24.4-25.9%, p = 0.078). Conclusions: The phantom-based correction method can provide standardized reference T1 values in healthy subjects. Key points: • After phantom-based correction, the global native T1 of 16 entire myocardial segments on 3-T cardiac MRI is 1289.4 ± 32.4 ms, and the extracellular volume fraction was 25.0 ± 2.7% for healthy subjects. • After phantom - based correction was applied, the differences in the global native T1 among institutions became insignificant, and the CoV also decreased from 3.0 to 2.5%. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Springer International | - |
dc.relation.isPartOf | EUROPEAN RADIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Contrast Media | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Healthy Volunteers | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Magnetic Resonance Imaging* / methods | - |
dc.subject.MESH | Magnetic Resonance Imaging, Cine | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Myocardium* / pathology | - |
dc.subject.MESH | Predictive Value of Tests | - |
dc.subject.MESH | Reference Standards | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.title | Phantom-based correction for standardization of myocardial native T1 and extracellular volume fraction in healthy subjects at 3-Tesla cardiac magnetic resonance imaging | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학교실) | - |
dc.contributor.googleauthor | Young Joo Suh | - |
dc.contributor.googleauthor | Pan Ki Kim | - |
dc.contributor.googleauthor | Jinho Park | - |
dc.contributor.googleauthor | Eun-Ah Park | - |
dc.contributor.googleauthor | Jung Im Jung | - |
dc.contributor.googleauthor | Byoung Wook Choi | - |
dc.identifier.doi | 10.1007/s00330-022-08936-8 | - |
dc.contributor.localId | A01892 | - |
dc.contributor.localId | A04059 | - |
dc.relation.journalcode | J00851 | - |
dc.identifier.eissn | 1432-1084 | - |
dc.identifier.pmid | 35771246 | - |
dc.subject.keyword | Heart | - |
dc.subject.keyword | Magnetic resonance imaging | - |
dc.subject.keyword | Phantoms, imaging | - |
dc.subject.keyword | Standardization | - |
dc.contributor.alternativeName | Suh, Young Joo | - |
dc.contributor.affiliatedAuthor | 서영주 | - |
dc.contributor.affiliatedAuthor | 최병욱 | - |
dc.citation.volume | 32 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 8122 | - |
dc.citation.endPage | 8130 | - |
dc.identifier.bibliographicCitation | EUROPEAN RADIOLOGY, Vol.32(12) : 8122-8130, 2022-12 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.