Contact lens-type ocular in vivo dosimeter for radiotherapy

DC Field Value Language
dc.contributor.authorKim, Jung-in-
dc.contributor.authorCho, Jin-dong-
dc.contributor.authorSon, Jaeman-
dc.contributor.authorChoi, Chang Heon-
dc.contributor.authorWu, Hong-Gyun-
dc.contributor.authorPark, Jong Min-
dc.date.accessioned2022-09-06T06:38:04Z-
dc.date.available2022-09-06T06:38:04Z-
dc.date.created2022-06-29-
dc.date.issued2020-02-
dc.identifier.issn0094-2405-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/190240-
dc.description.abstractPurpose This study aimed to (a) develop a contact lens-type ocular in vivo dosimeter (CLOD) that can be worn directly on the eye and (b) assess its dosimetric characteristics and biological stability for radiation therapy. Methods The molder of a soft contact lens was directly used to create the dosimeter, which included a radiation-sensitive component - an active layer similar to a radiochromic film - to measure the delivered dose. A flatbed scanner with a reflection mode was used to measure the change in optical density due to irradiation. The sensitivity, energy, dose rate, and angular dependence were tested, and the uncertainty in determining the dose was calculated using error propagation analysis. Sequential biological stability tests, specifically, cytotoxicity and ocular irritation tests, were conducted to ensure the safe application of the CLOD to patients. Results The dosimeter demonstrated high sensitivity in the low dose region, and the sensitivity linearly decreased with the dose. The responses obtained for the 10 and 15 MV photon beams were 1.7% and 1.9% higher compared to the 6 MV photon beam. A strong dose rate dependence was not obtained for the CLOD. Angular dependence was observed from 90 degrees to 180 degrees with a difference in response from 1% to 2%. The total uncertainty in error propagation analysis decreased as a function of the dose in the red channel. For a dose range of 0 to 50 cGy, the total uncertainties for 5, 10, and 50 cGy were 14.2%, 8.9%, and 5%, respectively. Quantitative evaluation using the MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) method presented no cytotoxicity. Further, no corneal opacity, iris reaction, or conjunctival inflammation was observed. Conclusions The CLOD is the first dosimeter that can be worn close to the eye. The results of cytotoxicity and irritation tests indicate that it is a stable medical device. The evaluation of dose characteristics in open field conditions shows that the CLOD can be applied to an in vivo dosimeter in radiotherapy.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherPublished for the American Assn. of Physicists in Medicine by the American Institute of Physics.-
dc.relation.isPartOfMedical Physics-
dc.relation.isPartOfMEDICAL PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleContact lens-type ocular in vivo dosimeter for radiotherapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorKim, Jung-in-
dc.contributor.googleauthorCho, Jin-dong-
dc.contributor.googleauthorSon, Jaeman-
dc.contributor.googleauthorChoi, Chang Heon-
dc.contributor.googleauthorWu, Hong-Gyun-
dc.contributor.googleauthorPark, Jong Min-
dc.identifier.doi10.1002/mp.13932-
dc.relation.journalcodeJ02206-
dc.identifier.eissn2473-4209-
dc.subject.keywordcontact lens dosimeter-
dc.subject.keywordlens dose-
dc.subject.keywordocular dosimeter-
dc.subject.keywordradiation therapy-
dc.contributor.affiliatedAuthorCho, Jin-dong-
dc.identifier.scopusid2-s2.0-85076119073-
dc.identifier.wosid000500247300001-
dc.citation.volume47-
dc.citation.number2-
dc.citation.startPage722-
dc.citation.endPage735-
dc.identifier.bibliographicCitationMedical Physics, Vol.47(2) : 722-735, 2020-02-
dc.identifier.rimsid74577-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorcontact lens dosimeter-
dc.subject.keywordAuthorlens dose-
dc.subject.keywordAuthorocular dosimeter-
dc.subject.keywordAuthorradiation therapy-
dc.subject.keywordPlusSTEREOTACTIC BODY RADIOTHERAPY-
dc.subject.keywordPlusEBT3 RADIOCHROMIC FILMS-
dc.subject.keywordPlusNORMAL TISSUE-
dc.subject.keywordPlusRADIATION-THERAPY-
dc.subject.keywordPlusMOSFET DOSIMETER-
dc.subject.keywordPlusTASK GROUP-
dc.subject.keywordPlusPHOTON-
dc.subject.keywordPlusCATARACT-
dc.subject.keywordPlusIMPACT-
dc.subject.keywordPlusHEAD-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
Appears in Collections:
7. Others (기타) > Others (기타) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.