0 358

Cited 0 times in

Spatiotemporal parameters from instrumented motion analysis represent clinical measurement of upper limb function in children with cerebral palsy

Authors
 Dain Shim  ;  Ja Young Choi  ;  Sook-Hee Yi  ;  Eun Sook Park  ;  Seungki Kim  ;  Beomki Yoo  ;  Dongho Park  ;  Hye-Rin Park  ;  Dong-Wook Rha 
Citation
 GAIT & POSTURE, Vol.91 : 326-331, 2022-01 
Journal Title
GAIT & POSTURE
ISSN
 0966-6362 
Issue Date
2022-01
MeSH
Cerebral Palsy* ; Child ; Female ; Humans ; Male ; Motion ; Movement ; Range of Motion, Articular ; Upper Extremity
Keywords
Cerebral palsy ; Motion analysis ; Reach and grasp cycle ; Spatiotemporal parameter ; Upper limb
Abstract
Background: There are various tools that measure upper limb function in children with cerebral palsy(CP) clinically, but these measurement methods are examiner-dependent and scale values are not proportional to the upper limb function which makes it difficult to quantify the function.

Research question: The purpose of this study was to investigate whether the new parameters derived from 3D motion analysis reflect the upper limb function which measured by Melbourne Assessment 2 (MA2) in children with cerebral palsy (CP) compared to the clinical measurements.

Methods: Forty children with CP (24 boys, 16 girls; mean [SD] age, 6 years 11 months [3 years 5 months]) were recruited. Motion capture was conducted during phases T1-T4 of Reach and Grasp Cycles. New parameters (movement time, number of movement units, index of curvature) were derived from wrist marker data. Range of motion (ROM), accuracy, dexterity, and fluency of unilateral upper limb function were assessed using MA2. Spearman rank coefficients were determined to evaluate correlations between MA2 and the new parameters.

Results and significance: Index of curvature correlated negatively with MA2 accuracy scores during T1 (rs -0.347, p < 0.05), T2 (rs -0.471, p < 0.01), and T3 (rs -0.660, p < 0.01). Number of movement units correlated negatively with MA2 ROM, accuracy, and fluency scores during T1 (ROM rs -0.334; accuracy rs -0.331; fluency rs -0.375; p < 0.05) and T3 (ROM rs -0.499; accuracy rs -0.531; fluency rs -0.515; p < 0.01). Index of curvature and number of movement units are objective, simple parameters showing fair to good correlation with MA2 accuracy and fluency of upper limb function.
Full Text
https://www.sciencedirect.com/science/article/pii/S0966636220306329?via%3Dihub
DOI
10.1016/j.gaitpost.2020.11.007
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Rehabilitation Medicine (재활의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Seung Ki(김승기) ORCID logo https://orcid.org/0000-0002-8823-6258
Rha, Dong Wook(나동욱) ORCID logo https://orcid.org/0000-0002-7153-4937
Park, Eun Sook(박은숙) ORCID logo https://orcid.org/0000-0002-9144-3063
Park, Hye-Rin(박혜린)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/189360
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.