Cited 1 times in

Feasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement: A Comparison With Contrast-Enhanced Computed Tomography

DC Field Value Language
dc.contributor.author고영국-
dc.contributor.author김영진-
dc.contributor.author서영주-
dc.contributor.author이삭-
dc.contributor.author홍그루-
dc.contributor.author홍명기-
dc.date.accessioned2022-03-11T10:58:59Z-
dc.date.available2022-03-11T10:58:59Z-
dc.date.issued2022-01-
dc.identifier.issn0363-8715-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/188084-
dc.description.abstractObjective: Noncontrast-enhanced (NCE) cross-sectional images other than contrast-enhanced (CE)-computed tomography (CT) may be necessary for annular sizing before transcatheter aortic valve replacement (TAVR), because of the risk of contrast-induced nephropathy. We aimed to investigate the feasibility of aortic annular measurements using NCE-CT in TAVR candidates by comparing them with CE-CT measurements. Methods: We retrospectively enrolled 46 patients who underwent CT for the purpose of pre-TAVR evaluation (17 men; mean age, 82.3 ± 5.0 years). On CE and NCE examination, measurements of the average diameter and perimeter of aortic annulus were performed by 2 observers, and coronary ostial heights were measured. Differences in annular parameters and coronary ostial heights between NCE and CE examinations were assessed using Bland-Altman analysis and intraclass correlation coefficients (ICCs). Results: Aortic annulus measurement values were significantly larger in the NCE examinations compared with those in the CE examinations according to both readers (mean differences of 0.8 mm for the average diameter and 2.1 mm for the perimeter according to observer 1, and 1.1 mm for the average diameter and 3.4 mm for the perimeter according to observer 2; ICC, 0.771-0.923). The mean difference between coronary ostial height measurement on NCE and CE examination was 0.6 mm for left coronary ostium (ICC, 0.795) and 0.7 mm for right coronary ostium (ICC, 0.802). No case showed disagreement between NCE and CE examinations for hypothetical valve sizing. Conclusions: Noncontrast-enhanced cardiac CT examination may be feasible for aortic annular measurements before TAVR and provides comparable measurement values to CE examination.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherLippincott Williams & Wilkins-
dc.relation.isPartOfJOURNAL OF COMPUTER ASSISTED TOMOGRAPHY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHAortic Valve* / diagnostic imaging-
dc.subject.MESHAortic Valve* / surgery-
dc.subject.MESHContrast Media-
dc.subject.MESHFeasibility Studies-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHPerioperative Period-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHTomography, X-Ray Computed / methods*-
dc.subject.MESHTranscatheter Aortic Valve Replacement / methods*-
dc.titleFeasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement: A Comparison With Contrast-Enhanced Computed Tomography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorYoung Joo Suh-
dc.contributor.googleauthorSak Lee-
dc.contributor.googleauthorGeu-Ru Hong-
dc.contributor.googleauthorYoung-Guk Ko-
dc.contributor.googleauthorMyeong-Ki Hong-
dc.contributor.googleauthorYoung Jin Kim-
dc.identifier.doi10.1097/RCT.0000000000001238-
dc.contributor.localIdA00127-
dc.contributor.localIdA00727-
dc.contributor.localIdA01892-
dc.contributor.localIdA02807-
dc.contributor.localIdA04386-
dc.contributor.localIdA04391-
dc.relation.journalcodeJ01350-
dc.identifier.eissn1532-3145-
dc.identifier.pmid35099136-
dc.identifier.urlhttps://journals.lww.com/jcat/Fulltext/2022/01000/Feasibility_of_Aortic_Annular_Measurements_Using.9.aspx-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.affiliatedAuthor고영국-
dc.contributor.affiliatedAuthor김영진-
dc.contributor.affiliatedAuthor서영주-
dc.contributor.affiliatedAuthor이삭-
dc.contributor.affiliatedAuthor홍그루-
dc.contributor.affiliatedAuthor홍명기-
dc.citation.volume46-
dc.citation.number1-
dc.citation.startPage50-
dc.citation.endPage55-
dc.identifier.bibliographicCitationJOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, Vol.46(1) : 50-55, 2022-01-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.