Fabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts

DC Field Value Language
dc.contributor.author강원준-
dc.contributor.author김민정-
dc.contributor.author김은경-
dc.contributor.author서진석-
dc.contributor.author양재문-
dc.contributor.author이영한-
dc.contributor.author허단-
dc.date.accessioned2022-03-11T05:58:39Z-
dc.date.available2022-03-11T05:58:39Z-
dc.date.issued2022-01-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/187889-
dc.description.abstractPurpose: The positron emission tomography (PET)-magnetic resonance (MR) system is a newly emerging technique that yields hybrid images with high-resolution anatomical and metabolic information. With PET-MR imaging, a definitive diagnosis of breast abnormalities will be possible with high spatial accuracy and images will be acquired for the optimal fusion of anatomic locations. Therefore, we propose a PET-compatible two-channel breast MR coil with minimal disturbance to image acquisition which can be used for simultaneous PET-MR imaging in patients with breast cancer. Materials and methods: For coil design and construction, the conductor loops of the Helmholtz coil were tuned, matched, and subdivided with nonmagnetic components. Element values were optimized with an electromagnetic field simulation. Images were acquired on a GE 600 PET-computed tomography (CT) and GE 3.0 T MR system. For this study, we used the T1-weighted image (volunteer; repetition time (TR), 694 ms; echo time (TE), 9.6 ms) and T2-weighted image (phantom; TR, 8742 ms; TE, 104 ms) with the fast spin-echo sequence. Results: The results of measuring image factors with the proposed radiofrequency (RF) coil and standard conventional RF coil were as follows: signal-to-noise ratio (breast; 207.7 vs. 175.2), percent image uniformity (phantom; 89.22%-91.27% vs. 94.63%-94.77%), and Hounsfield units (phantom; -4.51 vs. 2.38). Conclusions: Our study focused on the feasibility of proposed two-channel Helmholtz loops (by minimizing metallic components and soldering) for PET-MR imaging and found the comparable image quality to the standard conventional coil. We believe our work will help significantly to improve image quality with the development of a less metallic breast MR coil.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherWiley-
dc.relation.isPartOfJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHArtifacts*-
dc.subject.MESHBreast* / diagnostic imaging-
dc.subject.MESHHumans-
dc.subject.MESHMagnetic Resonance Imaging-
dc.subject.MESHPhantoms, Imaging-
dc.subject.MESHPositron-Emission Tomography-
dc.titleFabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Nuclear Medicine (핵의학교실)-
dc.contributor.googleauthorYoung Han Lee-
dc.contributor.googleauthorKyu-Ho Song-
dc.contributor.googleauthorJaemoon Yang-
dc.contributor.googleauthorWon Jun Kang-
dc.contributor.googleauthorKeum Sil Lee-
dc.contributor.googleauthorMin Jung Kim-
dc.contributor.googleauthorEun-Kyung Kim-
dc.contributor.googleauthorDan Heo-
dc.contributor.googleauthorBo-Young Choe-
dc.contributor.googleauthorJin-Suck Suh-
dc.identifier.doi10.1002/acm2.13483-
dc.contributor.localIdA00062-
dc.contributor.localIdA00473-
dc.contributor.localIdA00801-
dc.contributor.localIdA01916-
dc.contributor.localIdA02315-
dc.contributor.localIdA02967-
dc.relation.journalcodeJ03009-
dc.identifier.eissn1526-9914-
dc.identifier.pmid34854217-
dc.subject.keywordbreast imaging-
dc.subject.keywordmagnetic resonance imaging-
dc.subject.keywordmetallic artifact-
dc.subject.keywordpositron emission tomography-
dc.subject.keywordradiofrequency coil-
dc.contributor.alternativeNameKang, Won Jun-
dc.contributor.affiliatedAuthor강원준-
dc.contributor.affiliatedAuthor김민정-
dc.contributor.affiliatedAuthor김은경-
dc.contributor.affiliatedAuthor서진석-
dc.contributor.affiliatedAuthor양재문-
dc.contributor.affiliatedAuthor이영한-
dc.citation.volume23-
dc.citation.number1-
dc.citation.startPagee13483-
dc.identifier.bibliographicCitationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, Vol.23(1) : e13483, 2022-01-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.