491 853

Cited 0 times in

Cited 3 times in

Fabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts

DC Field Value Language
dc.contributor.authorLee, Young Han-
dc.contributor.authorSong, Kyu-Ho-
dc.contributor.authorYang, Jae Moon-
dc.contributor.authorKang, Won Jun-
dc.contributor.authorLee, Keum Sil-
dc.contributor.authorKim, Min Jung-
dc.contributor.authorKim, Eun Kyung-
dc.contributor.authorHeo, Dan-
dc.contributor.authorChoe, Bo-Young-
dc.contributor.authorSuh, Jin Suck-
dc.date.accessioned2022-03-11T05:58:39Z-
dc.date.available2022-03-11T05:58:39Z-
dc.date.created2022-06-08-
dc.date.issued2022-01-
dc.identifier.issn1526-9914-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/187889-
dc.description.abstractPurpose The positron emission tomography (PET)-magnetic resonance (MR) system is a newly emerging technique that yields hybrid images with high-resolution anatomical and metabolic information. With PET-MR imaging, a definitive diagnosis of breast abnormalities will be possible with high spatial accuracy and images will be acquired for the optimal fusion of anatomic locations. Therefore, we propose a PET-compatible two-channel breast MR coil with minimal disturbance to image acquisition which can be used for simultaneous PET-MR imaging in patients with breast cancer. Materials and Methods For coil design and construction, the conductor loops of the Helmholtz coil were tuned, matched, and subdivided with nonmagnetic components. Element values were optimized with an electromagnetic field simulation. Images were acquired on a GE 600 PET-computed tomography (CT) and GE 3.0 T MR system. For this study, we used the T1-weighted image (volunteer; repetition time (TR), 694 ms; echo time (TE), 9.6 ms) and T2-weighted image (phantom; TR, 8742 ms; TE, 104 ms) with the fast spin-echo sequence. Results The results of measuring image factors with the proposed radiofrequency (RF) coil and standard conventional RF coil were as follows: signal-to-noise ratio (breast; 207.7 vs. 175.2), percent image uniformity (phantom; 89.22%-91.27% vs. 94.63%-94.77%), and Hounsfield units (phantom; -4.51 vs. 2.38). Conclusions Our study focused on the feasibility of proposed two-channel Helmholtz loops (by minimizing metallic components and soldering) for PET-MR imaging and found the comparable image quality to the standard conventional coil. We believe our work will help significantly to improve image quality with the development of a less metallic breast MR coil.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.language영어-
dc.publisherAmerican Institute of Physics-
dc.relation.isPartOfJournal of applied clinical medical physics [electronic resource] / American College of Medical Physics-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleFabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Nuclear Medicine (핵의학교실)-
dc.contributor.googleauthorLee, Young Han-
dc.contributor.googleauthorSong, Kyu-Ho-
dc.contributor.googleauthorYang, Jae Moon-
dc.contributor.googleauthorKang, Won Jun-
dc.contributor.googleauthorLee, Keum Sil-
dc.contributor.googleauthorKim, Min Jung-
dc.contributor.googleauthorKim, Eun Kyung-
dc.contributor.googleauthorHeo, Dan-
dc.contributor.googleauthorChoe, Bo-Young-
dc.contributor.googleauthorSuh, Jin Suck-
dc.identifier.doi10.1002/acm2.13483-
dc.identifier.eissn1526-9914-
dc.subject.keywordbreast imaging-
dc.subject.keywordmagnetic resonance imaging-
dc.subject.keywordmetallic artifact-
dc.subject.keywordpositron emission tomography-
dc.subject.keywordradiofrequency coil-
dc.contributor.alternativeNameKang, Won Jun-
dc.contributor.affiliatedAuthorLee, Young Han-
dc.contributor.affiliatedAuthorYang, Jae Moon-
dc.contributor.affiliatedAuthorKang, Won Jun-
dc.contributor.affiliatedAuthorKim, Min Jung-
dc.contributor.affiliatedAuthorKim, Eun Kyung-
dc.contributor.affiliatedAuthorHeo, Dan-
dc.contributor.affiliatedAuthorSuh, Jin Suck-
dc.identifier.scopusid2-s2.0-85120455667-
dc.identifier.wosid000724683100001-
dc.citation.volume23-
dc.citation.number1-
dc.identifier.bibliographicCitationJournal of applied clinical medical physics [electronic resource] / American College of Medical Physics, Vol.23(1), 2022-01-
dc.identifier.rimsid74309-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorbreast imaging-
dc.subject.keywordAuthormagnetic resonance imaging-
dc.subject.keywordAuthormetallic artifact-
dc.subject.keywordAuthorpositron emission tomography-
dc.subject.keywordAuthorradiofrequency coil-
dc.subject.keywordPlusATTENUATION CORRECTION-
dc.subject.keywordPlusPET-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusREDUCTION-
dc.subject.keywordPlusPET/MRI-
dc.subject.keywordPlusCT-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.identifier.articlenoe13483-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.