Feasibility of Coronary Artery Calcium Scoring on Dual-Energy Chest Computed Tomography: A Prospective Comparison with Electrocardiogram-Gated Calcium Score Computed Tomography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김태훈 | - |
dc.contributor.author | 박철환 | - |
dc.contributor.author | 신재민 | - |
dc.date.accessioned | 2021-12-28T17:21:09Z | - |
dc.date.available | 2021-12-28T17:21:09Z | - |
dc.date.issued | 2021-02 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/187060 | - |
dc.description.abstract | Rationale and Objectives: This study aimed to evaluate the feasibility of assessment using the coronary artery calcium score (CACS) in dual-energy chest computed tomography (CT). Materials and Methods: We prospectively enrolled 30 patients (19 male, 11 female; mean age, 63.73 ± 9.40 years) who clinically required contrast-enhanced chest CT. The patients underwent electrocardiogram-gated cardiac calcium-scoring CT with a slice thickness of 2.5 mm followed by a sequentially non-gated contrast-enhanced dual-energy chest CT using 140/80 fast kVp switching technology with slice thicknesses of 1.25 mm and 2.5 mm. Virtual unenhanced (VUE) images were then reconstructed from the dual-energy CT using the material suppressed iodine (MSI) technique. Results: The mean heart rates were 63.33 ± 12.01 beats per minute. The mean CACS on the coronary calcium-scoring CT was 361.1 ± 435.5, and CACSs of the VUE images were 76.8 ± 128.6 (2.5 mm slice) and 108.7 ± 165.1 (1.25 mm slice). The correlation coefficients of CACS between the coronary calcium-scoring CT with the VUE 2.5 mm and 1.25 mm images were 0.888 and 0.904, respectively. The inter-observer agreements for the calcium score measurement between the calcium-scoring CT, VUE 2.5 mm, and VUE 1.25 mm were 1.000, 0.999, and 1.000, respectively. Conclusions: In conclusion, assessment of CACS using dual-energy chest CT might be feasible when using MSI virtual unenhanced dual-energy chest CT images with a slice thickness of 1.25 mm. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | MDPI AG | - |
dc.relation.isPartOf | JOURNAL OF CLINICAL MEDICINE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Feasibility of Coronary Artery Calcium Scoring on Dual-Energy Chest Computed Tomography: A Prospective Comparison with Electrocardiogram-Gated Calcium Score Computed Tomography | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학교실) | - |
dc.contributor.googleauthor | Sun Yong Lee | - |
dc.contributor.googleauthor | Tae Hoon Kim | - |
dc.contributor.googleauthor | Kyunghwa Han | - |
dc.contributor.googleauthor | Jae Min Shin | - |
dc.contributor.googleauthor | Ji Young Kim | - |
dc.contributor.googleauthor | Daein Kim | - |
dc.contributor.googleauthor | Chul Hwan Park | - |
dc.identifier.doi | 10.3390/jcm10040653 | - |
dc.contributor.localId | A01086 | - |
dc.contributor.localId | A01722 | - |
dc.contributor.localId | A05597 | - |
dc.relation.journalcode | J03556 | - |
dc.identifier.eissn | 2077-0383 | - |
dc.identifier.pmid | 33567707 | - |
dc.subject.keyword | ECG-gated cardiac CT | - |
dc.subject.keyword | coronary artery calcium score | - |
dc.subject.keyword | correlation coefficient | - |
dc.subject.keyword | dual-energy computed tomography | - |
dc.subject.keyword | wide-detector CT | - |
dc.contributor.alternativeName | Kim, Tae Hoon | - |
dc.contributor.affiliatedAuthor | 김태훈 | - |
dc.contributor.affiliatedAuthor | 박철환 | - |
dc.contributor.affiliatedAuthor | 신재민 | - |
dc.citation.volume | 10 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 653 | - |
dc.identifier.bibliographicCitation | JOURNAL OF CLINICAL MEDICINE, Vol.10(4) : 653, 2021-02 | - |