경관적 Stent-graft 삽입술을 이용한 대동맥류의 치료

DC Field Value Language
dc.contributor.author권혁문-
dc.contributor.author심원흠-
dc.contributor.author이도연-
dc.contributor.author장병철-
dc.contributor.author정남식-
dc.date.accessioned2021-12-27T17:32:25Z-
dc.date.available2021-12-27T17:32:25Z-
dc.date.issued1995-08-
dc.identifier.issn0301-2867-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/186718-
dc.description.abstractPurpose : The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft.Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose ofthis study was to evaluate the safety and effectiveness of a endoluminally placed Stent-graft for the treatment ofaortic aneurysms. Materials and Methods : Transluminal endovascular Stent-graft placements were attempted in 9patients with infra-renal aortic aneurysms(n=6), thoracic aortic aneurysm(n=1), and aortic dissection(n=2). Theendovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modifiedGianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 frenchsheath and expanded to 17-30mm in diameter. The endovascular therapy was performed using a common femoral arterycutdown with local anesthesia. Results : The endovascular Stent-graft deployment were achieved in 7 of 9 patients.Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There was completethrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and apersistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated byobliteration of entry tears. There were no major complication associated with Stent-graft placement. Conclusion :These preliminary results shows that transluminal endovascular Stent-grafts offers great promise and good results.Further investigation is needed to establish its long-term safety and efficacy.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한방사선의학회-
dc.relation.isPartOfJournal of the Korean Radiologist Society(대한방사선의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title경관적 Stent-graft 삽입술을 이용한 대동맥류의 치료-
dc.title.alternativeTransluminal Endovascular Stent-Graft for the Treatment of Aortic Aneurysms-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthor이도연-
dc.contributor.googleauthor장병철-
dc.contributor.googleauthor심원흠-
dc.contributor.googleauthor조승연-
dc.contributor.googleauthor정남식-
dc.contributor.googleauthor권혁문-
dc.contributor.googleauthor이영준-
dc.contributor.googleauthor이종태-
dc.identifier.doi10.3348/jkrs.1995.33.3.361-
dc.contributor.localIdA00260-
dc.contributor.localIdA02202-
dc.contributor.localIdA02718-
dc.contributor.localIdA03430-
dc.contributor.localIdA03585-
dc.relation.journalcodeJ01844-
dc.contributor.alternativeNameKwon, Hyuck Moon-
dc.contributor.affiliatedAuthor권혁문-
dc.contributor.affiliatedAuthor심원흠-
dc.contributor.affiliatedAuthor이도연-
dc.contributor.affiliatedAuthor장병철-
dc.contributor.affiliatedAuthor정남식-
dc.citation.volume33-
dc.citation.number3-
dc.citation.startPage361-
dc.citation.endPage366-
dc.identifier.bibliographicCitationJournal of the Korean Radiologist Society (대한방사선의학회지), Vol.33(3) : 361-366, 1995-08-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.