Cited 0 times in
경관적 Stent-graft 삽입술을 이용한 대동맥류의 치료
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 권혁문 | - |
dc.contributor.author | 심원흠 | - |
dc.contributor.author | 이도연 | - |
dc.contributor.author | 장병철 | - |
dc.contributor.author | 정남식 | - |
dc.date.accessioned | 2021-12-27T17:32:25Z | - |
dc.date.available | 2021-12-27T17:32:25Z | - |
dc.date.issued | 1995-08 | - |
dc.identifier.issn | 0301-2867 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/186718 | - |
dc.description.abstract | Purpose : The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft.Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose ofthis study was to evaluate the safety and effectiveness of a endoluminally placed Stent-graft for the treatment ofaortic aneurysms. Materials and Methods : Transluminal endovascular Stent-graft placements were attempted in 9patients with infra-renal aortic aneurysms(n=6), thoracic aortic aneurysm(n=1), and aortic dissection(n=2). Theendovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modifiedGianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 frenchsheath and expanded to 17-30mm in diameter. The endovascular therapy was performed using a common femoral arterycutdown with local anesthesia. Results : The endovascular Stent-graft deployment were achieved in 7 of 9 patients.Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There was completethrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and apersistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated byobliteration of entry tears. There were no major complication associated with Stent-graft placement. Conclusion :These preliminary results shows that transluminal endovascular Stent-grafts offers great promise and good results.Further investigation is needed to establish its long-term safety and efficacy. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한방사선의학회 | - |
dc.relation.isPartOf | Journal of the Korean Radiologist Society(대한방사선의학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 경관적 Stent-graft 삽입술을 이용한 대동맥류의 치료 | - |
dc.title.alternative | Transluminal Endovascular Stent-Graft for the Treatment of Aortic Aneurysms | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학교실) | - |
dc.contributor.googleauthor | 이도연 | - |
dc.contributor.googleauthor | 장병철 | - |
dc.contributor.googleauthor | 심원흠 | - |
dc.contributor.googleauthor | 조승연 | - |
dc.contributor.googleauthor | 정남식 | - |
dc.contributor.googleauthor | 권혁문 | - |
dc.contributor.googleauthor | 이영준 | - |
dc.contributor.googleauthor | 이종태 | - |
dc.identifier.doi | 10.3348/jkrs.1995.33.3.361 | - |
dc.contributor.localId | A00260 | - |
dc.contributor.localId | A02202 | - |
dc.contributor.localId | A02718 | - |
dc.contributor.localId | A03430 | - |
dc.contributor.localId | A03585 | - |
dc.relation.journalcode | J01844 | - |
dc.contributor.alternativeName | Kwon, Hyuck Moon | - |
dc.contributor.affiliatedAuthor | 권혁문 | - |
dc.contributor.affiliatedAuthor | 심원흠 | - |
dc.contributor.affiliatedAuthor | 이도연 | - |
dc.contributor.affiliatedAuthor | 장병철 | - |
dc.contributor.affiliatedAuthor | 정남식 | - |
dc.citation.volume | 33 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 361 | - |
dc.citation.endPage | 366 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Radiologist Society (대한방사선의학회지), Vol.33(3) : 361-366, 1995-08 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.