0 462

Cited 2 times in

Effect of different driver power amplitudes on liver stiffness measurement in pediatric liver MR elastography

DC Field Value Language
dc.contributor.author고홍-
dc.contributor.author김승-
dc.contributor.author김지수-
dc.contributor.author신현주-
dc.contributor.author윤혜성-
dc.contributor.author이미정-
dc.contributor.author한석주-
dc.contributor.author한경화-
dc.date.accessioned2021-10-21T00:11:20Z-
dc.date.available2021-10-21T00:11:20Z-
dc.date.issued2021-10-
dc.identifier.issn2366-004X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/185415-
dc.description.abstractPurpose: To assess how different driver power amplitudes affect the measurement of liver stiffness in pediatric liver magnetic resonance elastography (MRE). Methods: From January 2018 to May 2018, pediatric patients (≤ 18 years) who underwent liver MRE with 20% and 56% driver power amplitudes were included in this retrospective study. Region-of-interests (ROIs) were drawn on four stiffness maps to include the largest area of the liver parenchyma. Intraclass correlation coefficients (ICCs) were used to assess agreements for the area, mean, maximum, minimum and standard deviation of liver stiffness between the driver power amplitudes. Results: 128 MRE stiffness maps from 16 patients (M:F = 10:6, median 12.5 years old) were included. On MRE, median ROI areas of liver were 83.1 cm2 (range, 46.9-144.1 cm2) and 63.0 cm2 (range, 5.4-123.4 cm2) for the driver power amplitudes of 20% and 56%, respectively. Median liver stiffness values were 2.3 kPa (range, 1.7-8.0 kPa) and 2.8 kPa (range, 1.7-8.5 kPa). Maximum and minimum liver stiffness values were 5.3 kPa and 1.0 kPa for 20% and 7.8 kPa and 1.1 kPa for 56%. Standard deviation was 0.6 kPa for 20% and 1.0 kPa for 56%. ICC values between the two power amplitudes were 0.33-0.51 for the ROI area and the maximum, minimum and standard deviation values of liver stiffness. The ICC value for liver stiffness was 0.857 (95% confidence interval, 0.760-0.915). Conclusion: Liver stiffness with two driver power amplitudes on MRE showed good reliability in pediatric patients. Driver power amplitudes need to be optimized according to the pediatric liver size.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringer-
dc.relation.isPartOfABDOMINAL RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHChild-
dc.subject.MESHEcho-Planar Imaging-
dc.subject.MESHElasticity Imaging Techniques*-
dc.subject.MESHHumans-
dc.subject.MESHLiver / diagnostic imaging-
dc.subject.MESHMagnetic Resonance Imaging-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHRetrospective Studies-
dc.titleEffect of different driver power amplitudes on liver stiffness measurement in pediatric liver MR elastography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Pediatrics (소아과학교실)-
dc.contributor.googleauthorDong-Kyu Kim-
dc.contributor.googleauthorHaesung Yoon-
dc.contributor.googleauthorKyunghwa Han-
dc.contributor.googleauthorJisoo Kim-
dc.contributor.googleauthorMi-Jung Lee-
dc.contributor.googleauthorSeung Kim-
dc.contributor.googleauthorHong Koh-
dc.contributor.googleauthorSeok Joo Han-
dc.contributor.googleauthorHyun Joo Shin-
dc.identifier.doi10.1007/s00261-021-03197-3-
dc.contributor.localIdA00156-
dc.contributor.localIdA00651-
dc.contributor.localIdA06048-
dc.contributor.localIdA02178-
dc.contributor.localIdA04989-
dc.contributor.localIdA02774-
dc.contributor.localIdA04288-
dc.relation.journalcodeJ03314-
dc.identifier.eissn2366-0058-
dc.identifier.pmid34216244-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs00261-021-03197-3-
dc.subject.keywordChild-
dc.subject.keywordElasticity Imaging Techniques-
dc.subject.keywordHumans-
dc.subject.keywordLiver-
dc.subject.keywordRetrospective Studies-
dc.contributor.alternativeNameKoh, Hong-
dc.contributor.affiliatedAuthor고홍-
dc.contributor.affiliatedAuthor김승-
dc.contributor.affiliatedAuthor김지수-
dc.contributor.affiliatedAuthor신현주-
dc.contributor.affiliatedAuthor윤혜성-
dc.contributor.affiliatedAuthor이미정-
dc.contributor.affiliatedAuthor한석주-
dc.citation.volume46-
dc.citation.number10-
dc.citation.startPage4729-
dc.citation.endPage4735-
dc.identifier.bibliographicCitationABDOMINAL RADIOLOGY, Vol.46(10) : 4729-4735, 2021-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pediatrics (소아과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.