159 386

Cited 1 times in

Assessment of Image Quality for Selective Intracoronary Contrast-Injected CT Angiography in a Hybrid Angio-CT System: A Feasibility Study in Swine

Authors
 Seongmin Ha  ;  Sunghee Jung  ;  Hyung Bok Park  ;  Sanghoon Shin  ;  Reza Arsanjani  ;  Youngtaek Hong  ;  Byoung Kwon Lee  ;  Yeonggul Jang  ;  Byunghwan Jeon  ;  Se Il Park  ;  Hackjoon Shim  ;  Hyuk Jae Chang 
Citation
 YONSEI MEDICAL JOURNAL, Vol.62(3) : 200-208, 2021-03 
Journal Title
YONSEI MEDICAL JOURNAL
ISSN
 0513-5796 
Issue Date
2021-03
MeSH
Animals ; Computed Tomography Angiography* ; Contrast Media / chemistry* ; Coronary Angiography* ; Coronary Vessels ; Feasibility Studies ; Female ; Image Enhancement* ; Image Processing, Computer-Assisted ; Radiation Dosage ; Swine
Keywords
Computed tomography angiography ; contrast media ; image quality enhancement ; percutaneous coronary intervention
Abstract
Purpose: To compare image quality in selective intracoronary contrast-injected computed tomography angiography (Selective-CTA) with that in conventional intravenous contrast-injected CTA (IV-CTA).

Materials and methods: Six pigs (35 to 40 kg) underwent both IV-CTA using an intravenous injection (60 mL) and Selective-CTA using an intracoronary injection (20 mL) through a guide-wire during/after percutaneous coronary intervention. Images of the common coronary artery were acquired. Scans were performed using a combined machine comprising an invasive coronary angiography suite and a 320-channel multi-slice CT scanner. Quantitative image quality parameters of CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), mean lumen diameter (MLD), and mean lumen area (MLA) were measured and compared. Qualitative analysis was performed using intraclass correlation coefficient (ICC), which was calculated for analysis of interobserver agreement.

Results: Quantitative image quality, determined by assessing the uniformity of CT attenuation (399.06 vs. 330.21, p<0.001), image noise (24.93 vs. 18.43, p<0.001), SNR (16.43 vs. 18.52, p=0.005), and CNR (11.56 vs. 13.46, p=0.002), differed significantly between IV-CTA and Selective-CTA. MLD and MLA showed no significant difference overall (2.38 vs. 2.44, p=0.068, 4.72 vs. 4.95, p=0.078). The density of contrast agent was significantly lower for selective-CTA (13.13 mg/mL) than for IV-CTA (400 mg/mL). Agreement between observers was acceptable (ICC=0.79±0.08).

Conclusion: Our feasibility study in swine showed that compared to IV-CTA, Selective-CTA provides better image quality and requires less iodine contrast medium.
Files in This Item:
T202100784.pdf Download
DOI
10.3349/ymj.2021.62.3.200
Appears in Collections:
1. College of Medicine (의과대학) > BioMedical Science Institute (의생명과학부) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Byoung Kwon(이병권) ORCID logo https://orcid.org/0000-0001-9259-2776
Chang, Hyuk-Jae(장혁재) ORCID logo https://orcid.org/0000-0002-6139-7545
Jung, Sunghee(정성희)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/182238
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links