0 665

Cited 0 times in

Cited 14 times in

Liver MRI with amide proton transfer imaging: feasibility and accuracy for the characterization of focal liver lesions

Authors
 Seo, Nieun  ;  Jeong, Ha-Kyu  ;  Choi, Jin-Young  ;  Park, Mi-Suk  ;  Kim, Myeong-Jin  ;  Chung, Yong Eun 
Citation
 EUROPEAN RADIOLOGY, Vol.31(1) : 222-231, 2021-01 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2021-01
Keywords
Magnetic resonance imaging ; Liver ; Hepatocellular carcinoma ; Amides ; Feasibility studies
Abstract
Objective To investigate the feasibility of using amide proton transfer (APT) magnetic resonance imaging (MRI) in the liver and to evaluate its ability to characterize focal liver lesions (FLLs). Methods A total of 203 patients with suspected FLLs who underwent APT imaging at 3T were included. APT imaging was obtained using a single-slice turbo spin-echo sequence to include FLLs through five breath-holds, and its acquisition time was approximately 1 min. APT signals in the background liver and FLL were measured with magnetization transfer ratio asymmetry (MTRasym) at 3.5 ppm. The technical success rate of APT imaging and the reasons for failure to obtain meaningfulMTR(asym)values were assessed. The Mann WhitneyUtest was used to compareMTR(asym)values between different FLLs. Results The technical success rate of APT imaging in the liver was 62.1% (126/203). The reasons for failure were a too large B(0)inhomogeneity (n = 43), significant respiratory motion (n = 12), and these two factors together (n = 22), respectively. Among 59 FLLs with analyzable APT images,MTR(asym)values were compared between 27 patients with liver metastases and 23 patients with hepatocellular carcinomas (HCCs). TheMTR(asym)values of metastases were significantly higher than those of HCC (0.13 +/- 2.15% vs. - 1.41 +/- 3.68%,p = 0.027). Conclusions APT imaging could be an imaging biomarker for the differentiation of FLLs. However, further technical improvement is required before APT imaging can be clinically applied to liver MRI.
DOI
10.1007/s00330-020-07122-y
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Myeong Jin(김명진) ORCID logo https://orcid.org/0000-0001-7949-5402
Park, Mi-Suk(박미숙) ORCID logo https://orcid.org/0000-0001-5817-2444
Seo, Nieun(서니은) ORCID logo https://orcid.org/0000-0001-8745-6454
Chung, Yong Eun(정용은) ORCID logo https://orcid.org/0000-0003-0811-9578
Choi, Jin Young(최진영) ORCID logo https://orcid.org/0000-0002-9025-6274
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/181991
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links