245 369

Cited 13 times in

Coronary artery calcium scoring on non-gated, non-contrast chest computed tomography (CT) using wide-detector, high-pitch and fast gantry rotation: comparison with dedicated calcium scoring CT

Authors
 Jae Min Shin  ;  Tae Hoon Kim  ;  Ji Young Kim  ;  Chul Hwan Park 
Citation
 JOURNAL OF THORACIC DISEASE, Vol.12(10) : 5783-5793, 2020-10 
Journal Title
JOURNAL OF THORACIC DISEASE
ISSN
 2072-1439 
Issue Date
2020-10
Keywords
Agatston score ; calcium score ; cardiac computed tomography (cardiac CT) ; chest computed tomography (chest CT) ; high pitch
Abstract
Background: Our study assessed the reliability of non-gated, non-contrast chest computed tomography (NCCT) (with high pitch, wide coverage, and fast gantry rotation time, reconstructed at various slice thicknesses), compared with the electrocardiography (ECG)-gated calcium scoring cardiac computed tomography (CaCT), for quantifying coronary artery calcification (CAC).

Methods: Patients aged ≥50 years who required clinical NCCT were prospectively enrolled. All CT scans were performed with 256-detector rows; z-axis coverage, 8 cm; pitch, 1.5; and gantry rotation time, 280 ms (table feed, 42.86 cm/s). NCCT was followed by ECG-gated CaCT. The NCCT images were reconstructed at 0.625-, 1.25-, and 2.5-mm slice intervals. The CAC score was calculated on four sets of CT images with a commercially available software using the Agatston method. The CAC scores were divided into four standard Agatston scoring categories (Agatston scores: 0, 1-100, 101-400, and >400). The inter-observer and inter-technique agreements were evaluated for the CAC scores.

Results: Twenty-six patients (M:F, 14:12; mean age, 66.04±6.97 years) were evaluated. Agatston scores showed near-perfect correlation between CaCT and NCCT for each slice thickness. On Bland-Altman analysis, the mean differences of Agatston scores between CaCT and NCCT (slice thicknesses: 0.625, 1.25, and 2.5 mm) were 37.54, 6.67, and -41.04, respectively. Inter-technique concordance was high for the four Agatston scoring categories with linear-weighted kappa values of 0.599, 0.609, and 0.597 for NCCT (slice thicknesses: 0.625, 1.25, and 2.5 mm, respectively). NCCT with 1.25-mm slice thickness showed the strongest correlation with CaCT.

Conclusions: CAC quantification with NCCT using a wide detector, high pitch, and high temporal resolution scanning modes correlates very highly with ECG-gated CaCT, and 1.25-mm slice thickness NCCT images are more reliable than other NCCT images.
Files in This Item:
T202005381.pdf Download
DOI
10.21037/jtd-20-1371
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Tae Hoon(김태훈) ORCID logo https://orcid.org/0000-0003-3598-2529
Park, Chul Hwan(박철환) ORCID logo https://orcid.org/0000-0002-0004-9475
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/181307
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links