0 331

Cited 27 times in

StatNet: Statistical Image Restoration for Low-Dose CT using Deep Learning

DC Field Value Language
dc.contributor.author김성원-
dc.contributor.author임준석-
dc.date.accessioned2020-12-01T17:38:53Z-
dc.date.available2020-12-01T17:38:53Z-
dc.date.issued2020-10-
dc.identifier.issn1932-4553-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/180365-
dc.description.abstractDeep learning has recently attracted widespread interest as a means of reducing noise in low-dose CT (LDCT) images. Deep convolutional neural networks (CNNs) are typically trained to transfer high-quality image features of normal-dose CT (NDCT) images to LDCT images. However, existing deep learning approaches for denoising LDCT images often overlook the statistical property of CT images. In this paper, we propose an approach to statistical image restoration for LDCT using deep learning. We introduce a loss function to incorporate the noise property in image domain derived from the noise statistics in sinogram domain. In order to capture the spatially-varying statistics of CT images, we increase the receptive fields of the neural network to cover full-size CT slices. In addition, the proposed network utilizes z-directional correlation by taking multiple consecutive CT slices as input. For performance evaluation, the proposed networks are trained and validated with a public dataset consisting of LDCT-NDCT image pairs. We also perform a retrospective study by testing the networks with clinical LDCT images. The experimental results show that the denoising networks successfully reduce the noise level and restore the image details without adding artifacts. This study demonstrates that the statistical deep learning approach can restore the image quality of LDCT without loss of anatomical information.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherIEEE-
dc.relation.isPartOfIEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleStatNet: Statistical Image Restoration for Low-Dose CT using Deep Learning-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthorKihwan Choi-
dc.contributor.googleauthorJoon Seok Lim-
dc.contributor.googleauthorSungwon Kim-
dc.identifier.doi10.1109/JSTSP.2020.2998413-
dc.contributor.localIdA05309-
dc.contributor.localIdA03408-
dc.relation.journalcodeJ03930-
dc.identifier.eissn1941-0484-
dc.identifier.urlhttps://ieeexplore.ieee.org/abstract/document/9103190-
dc.contributor.alternativeNameKim, Sungwon-
dc.contributor.affiliatedAuthor김성원-
dc.contributor.affiliatedAuthor임준석-
dc.citation.volume14-
dc.citation.number6-
dc.citation.startPage1137-
dc.citation.endPage1150-
dc.identifier.bibliographicCitationIEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, Vol.14(6) : 1137-1150, 2020-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.