Cited 13 times in
Effect of image quality fluctuations on the repeatability of thickness measurements in swept-source optical coherence tomography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김찬윤 | - |
dc.contributor.author | 배형원 | - |
dc.contributor.author | 성공제 | - |
dc.contributor.author | 이상엽 | - |
dc.contributor.author | 이혜선 | - |
dc.date.accessioned | 2020-12-01T16:49:12Z | - |
dc.date.available | 2020-12-01T16:49:12Z | - |
dc.date.issued | 2020-08 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/179991 | - |
dc.description.abstract | This study investigated the effect of image quality fluctuations on the repeatability of thickness measurements of the peripapillary retinal nerve fibre (PP-RNFL) and ganglion cell-inner plexiform (GC-IPL) layers using swept-source optical coherence tomography (SS-OCT). Three consecutive OCT scans each were performed on 56 healthy subject. Finally, 168 SS-OCT results were analysed. Based on the tertile values of the mean absolute difference of image quality score, all subjects were divided into the following three groups-low-(LIQD), moderate-(MIQD), and high-(HIQD) image quality score difference groups. A linear mixed model and intraclass correlation coefficients (ICCs) were used for analyses. Despite high ICC values (> 0.9), several sectors showed significant differences in the ICC values in intergroup comparisons. For LIQD-HIQD and MIQD-HIQD, most PP-RNFL sectors showed significant differences. For GC-IPL sectors, the LIQD-HIQD comparison showed significant differences in the temporosuperior (p = 0.012), inferior (p < .001), and temporoinferior (p = 0.042) sectors. Significant differences existed in the average GC-IPL (p = 0.009), nasoinferior (p = 0.035), and inferior GC-IPL sectors (p < .001) for MIQD-HIQD comparison. With higher image quality fluctuations, the repeatability of SS-OCT decreased in several sectors, which are considered clinically relevant in evaluating glaucoma status. Therefore, maintaining high-quality image status is essential to enhance the reliability of SS-OCT. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | Nature Publishing Group | - |
dc.relation.isPartOf | SCIENTIFIC REPORTS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Effect of image quality fluctuations on the repeatability of thickness measurements in swept-source optical coherence tomography | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학교실) | - |
dc.contributor.googleauthor | Heon Yang | - |
dc.contributor.googleauthor | Hye Sun Lee | - |
dc.contributor.googleauthor | Hyoung Won Bae | - |
dc.contributor.googleauthor | Gong Je Seong | - |
dc.contributor.googleauthor | Chan Yun Kim | - |
dc.contributor.googleauthor | Sang Yeop Lee | - |
dc.identifier.doi | 10.1038/s41598-020-70852-y | - |
dc.contributor.localId | A01035 | - |
dc.contributor.localId | A01814 | - |
dc.contributor.localId | A01946 | - |
dc.contributor.localId | A02820 | - |
dc.contributor.localId | A03312 | - |
dc.relation.journalcode | J02646 | - |
dc.identifier.eissn | 2045-2322 | - |
dc.identifier.pmid | 32807868 | - |
dc.contributor.alternativeName | Kim, Chan Yun | - |
dc.contributor.affiliatedAuthor | 김찬윤 | - |
dc.contributor.affiliatedAuthor | 배형원 | - |
dc.contributor.affiliatedAuthor | 성공제 | - |
dc.contributor.affiliatedAuthor | 이상엽 | - |
dc.contributor.affiliatedAuthor | 이혜선 | - |
dc.citation.volume | 10 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 13897 | - |
dc.identifier.bibliographicCitation | SCIENTIFIC REPORTS, Vol.10(1) : 13897, 2020-08 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.